Sound Testing In Coventry

Sound Testing in Coventry

APT Sound Testing provides UKAS accredited sound testing throughout Coventry and Warwickshire, providing you with precompletion sound test reports for your building control officer with a quick and reliable turnaround.

We provide a friendly and professional sound and acoustic testing service, covering many areas including Stratford Upon Avon, Tamworth, Solihull and Dudley, Warwick, Sutton Coldfield and Nuneaton to help you achieve the requirements of Approved Document E and attain building control signoff.

If you have a single dwelling or a site containing hundreds of units, we can help you to achieve compliance. We offer a one stop testing solution encompassing acoustic design of party walls and floors and precompletion sound testing once the building works are completed. We can also offer large cost savings for developers requiring multiple services such as SAP Calculations, Air Tightness Testing, Sound Insulation Testing and Extract Fan Testing, all these services can be provided in once seamless cost effective solution.

We also provide our ‘one stop acoustic solution’ for developers who specialise in conversion projects. This encompasses sample sound testing, acoustic design and precompletion sound testing. This provides an overview of insulation performance of the existing party walls and floors, which allows the acoustic design to be more targeted, which allows clients to save time and money during the acoustic upgrades.

As we are a multi UKAS accredited testing laboratory, you can be sure our reportage is of the highest standard and will be accepted by the tasked Coventry building control body. As all our testing is carried out in house (we do not subcontract work) which allows us to provide highly competitive pricing whilst maintaining the highest testing standards. It is our ongoing aim to provide a friendly and proactive service from design stage to handover.

If you require acoustic design or sound testing on your Coventry project, please contact us on 01525 303905, or email us at info@aptsoundtesting.co.uk.

Alternately, please check our frequently asked questions below for more information.

How can we help you?

If you're looking for an expert acoustic consultant or noise engineer, get in touch.

Contact Us

Why Choose Us

  • We strive to get you a pass
  • Competitive pricing
  • Friendly and proactive service
  • Experienced consultants
  • UKAS & ISO Accredited
  • Fast Response
  • Rapid Turnaround of Results
  • Nationwide coverage
  • Single precompletion solution
Contact Us Today!

Sound insulation testing is measuring the airborne or impact noise coming through a partition. The partition is the floor, wall or ceiling and there will be different requirements for each. Part E Building Regulations, England, Wales and Northern Ireland, is a set of regulations for both new build and conversion residential builds. Approved Document E was introduced in 2003, as a way of protecting residents from noise between dwellings. The regulations apply to all new-build and conversion constructions with residences next to one another.

A pair of airborne wall sound insulation tests can be completed in 1-2 hours. A 6 pack containing 2 airborne wall, 2 airborne floor and 2 impact floor tests will usually take 2-3 hours. For larger developments, such as apartment blocks, it would be worth allowing up to 2-3 hours for each 6 pack of sound tests; e.g. 12 tests would take 4-6 hours. We usually supply a full testing schedule with each quote, to ensure you comply with Building Regulations and to help you prepare correct plots for testing.

Approved Document E, requires that various walls and floors are tested between adjoining dwellings. The exact number of walls requiring testing will vary depending on the overall size of the development and the amount of different types of wall or floor constructions. On a typical small to medium development consisting of up to 10 dwellings with the same partition construction the project will usually require one single 6 pack. This consists of 2 airborne wall tests, 2 airborne floor tests and 2 impact floor tests. On a pair of semi-detached houses you may only require 2 airborne sound tests through the walls.

It depends on the location and the number of sound tests that are required on each site; it can be as low as £75 plus VAT per test if we are undertaking multiple tests. Please contact us at info@aptsoundtesting.co.uk to obtain a no obligation quote along with some friendly advice for you project.

UKAS accredited sound testing strictly follows ISO 16283 and the standards surrounding ‘calibration’, the process that makes sure all recording devices are operating without the fluctuation that gives a bias to specific frequencies. All testing equipment needs to be set at the correct amount and across these standards so that testing can be undertaken consistently at all times.Airborne sound testing is carried out using the following test methodology:

  1. A sound Level Meter gathers the ‘background noise level’ of the room, taking external noises into account, those such as road traffic can have a significant impact.
  2. A large dodecahedron speaker is placed in the transmitting room (on the other side of the partition, usually next door) and is measured in the receiving room, on the other side.
  3. The rooms ‘reverberation level’ is gathered first in the receiving room and source room to measure its ‘reflectiveness’ and its ‘decay time’, the amount of time it takes for a sound to dissipate.
  4. You then measure in the receiving room with a Sound Level Meter to assess the levels of sound transmission.
  5. The process above is repeated by moving both the speaker and measuring location to numerous locations in the rooms so that any resonances and anomalies are gathered.

In all cases the more complete a development, the more likely it is to meet air testing requirements. When we send out our quotation we also forward a specific air leakage checklist to help our client prepare for the testing.

Basically if you meet the following criteria will generally have a much better chance of passing the testing at the first attempt.

a. The building envelope should be fully complete; this includes walls, floors and ceilings.
b. All doors and windows must be fully fitted and able to shut tightly against their seals.
c. All electric fittings must be installed and functional.
d. All mechanical fittings must be installed and functional.
e. Gaps within walls and floors must be sealed.
f. All service penetrations must be fully sealed through the building envelope.
g. Bathrooms and kitchens must be fully fitted and all service penetrations sealed.
h. All mechanical ventilation turned off with grilles sealed.
i. All trickle vents to windows and doors must be sealed.
j. All fireplaces must be sealed.
k. Ensure water is present in soil pipes.
l. 240v power must be available on site.

To pass your sound insulation testing in compliance with Approved Document E, you will need to achieve the following sound insulation results:For separating floors & walls on new build projects

  • Separating Floor Between Flats Airborne Noise Reduction = 45dB Dn T,w + (Ctr) or greater
  • Separating Floor Between Flats Impact Noise Reduction = 62dB Ln T,w or less
  • Airborne Wall Tests to achieve 45dB Dn T,w + (Ctr) or more

For separating floors & walls on conversion projects

  • Separating Floor Between Flats Airborne Noise Reduction = 43dB Dn T,w + (Ctr) or greater
  • Separating Floor Between Flats Impact Noise Reduction = 64dB Ln T,w or less
  • Airborne Wall Tests to achieve 43dB Dn T,w + (Ctr) or more

In all cases the more complete a development, the more likely it is to pass the sound test and achieve the requirements of Approved Document E. When we send out our quotation we also forward a specific sound insulation checklist to help our client prepare for the testing.

Basically if you meet the following criteria will generally have a much better chance of passing the testing at the first attempt.

1.Site noise should be kept to a minimum with no power tools, generators, radios, fire alarms etc. operating
2.Walls, floors and ceilings must be completed
3.Windows & external doors must be fully fitted, glazed and closed
4.Any ventilation systems should be installed and closed
5.Internal doors should be hung and closed.
6.Skirting boards, electrical sockets and light switches should be fitted.
7.To test impact sound transmission, we can only test the fabric of the building, therefore there must be no additional final finish floorings fitted
8.Rooms in which testing is to be carried out should be empty and tidy with safe access.
9.No-one else should be working in the building during the test
10.Free access to the properties on both sides of the separating partition is required
11.240v (50Hz) mains power is required within the property to run our test equipment

Firstly don’t panic. If you’re sound test fails we can recommend an acoustic upgrade to help you pass the sound test in compliance with Approved Document E.

Coventry areas covered

We provide our services throughout the following towns in Coventry via our friendly and helpful engineers. Click on your local Coventry office location for more information.

Thermal-imaging-to-find-building-faults-save-money

Saving money with thermal imaging inspections

Thermal imaging inspections can be a great way to save money on long term building maintenance and energy costs! Here’s how they can help you save costs and improve safety: Cost Savings with Thermal Imaging Inspections Improving…
Sound-Testing-floors-n-London

Pre & Post Construction Sound Testing methodology

The preconstruction sound testing methodology involves several steps to ensure accurate results. Here’s a general guide for sound testing floors in flats: Preconstruction sound testing methodology Planning the preconstruction test:…
pre-works-Impact-sound-testing-on-floors

Pre & Post Construction Sound Testing to Floors

The pre and post Construction sound testing of floors in apartments that are under going floor upgrades, is an important part of ensuring that party floor meets the required sound…