Room Integrity Test Failures due to Leaky Enclosures

Room Integrity Test Failures due to Leaky Enclosures

In our experience the majority of room integrity test failures are caused by the lack of enclosure integrity, and/or the ability of the enclosure to adequately retain the extinguishant agent. Often the correct initial design concentration can be achieved but the enclosure is not able to retain the extinguishant agent for the required holding period due to the large amount of air leakage paths.

Enclosure Integrity Testing to a server room in central London

If the protected enclosure has failed the room integrity test, remedial work should be undertaken to reduce the air leakage paths within the building envelope, this may include;

              1. Check all doors and access panels are closing tightly against there proprietary frames.
              2. Sealing all cracks or penetrations leading into or out of the protected enclosure.
              3. Sealing all pipe chases and cable trays to be sealed around the outside and inside where they penetrate the perimeter boundaries of the protected enclosure.
              4. Walls to be caulked around the inside perimeter at the floor and ceiling junctions.
              5. Sealing of porous blockwork walls – this can be remedied by painting and ensuring the mortar joints are full.
              6. The addition of door sweeps or drop seals, weather stripping around jambs.
              7. Sealing of windows/glazed sections to the area.
              8. The sealing of the underside of doorways within the floor void.
              9. Ensure that air conditioning dampers are closing properly.

If you need advice on how to seal your server room or data center, please contact us now. We use the latest testing technology to provide thorough assessments of potential areas of air leakage and advice and recommendations on sealing as well full retention and remedial sealing reports.

Room integrity testing to a server room in Central London

 

APT undertakes Integrity Testing to server Rooms 

We undertake Room Integrity Testing on all types of protected enclosures across Central London and the South East. Our Engineers have over 40 years combined experience within the Fire Suppression Industry and are able to provide help and advice on your Room Integrity Test needs. We can also help if you have previously failed your integrity test, we can visit site and undertake localised smoke testing with air leakage reports. We can even undertake the fire sealing works if so required. It is our ongoing aim to provide clients a ‘one stop’ Room Integrity Testing service to cater for their most exacting requirements. We only use high quality equipment that is UKAS calibrated – a basic requirement of a UKAS accredited testing laboratory.

If you have a protected enclosure that requires a room integrity test, please contact us at: info@airpressuretesting.net or call Darren direct on 07775623464. We undertake testing throughout London and the South East.