Air Testing for Data Centre COLOs & HAC Corridors

Air Testing for COLOs & HAC Corridors in Data Centres

Industry‑Leading Air Leakage Testing for COLO Data Centres & HAC Corridors

APT provide Industry‑Leading Air Leakage Testing for COLO Data Centres & HAC Corridors specialist air leakage testing for COLO suites, data halls, and Hot Aisle Containment (HAC) corridors, helping operators achieve maximum cooling efficiency, stable rack inlet temperatures, and full compliance with modern data‑centre airflow standards. We are a UKAS accredited air test laboratory so you can be sure our testing and reportage is of the highest standard at all times.

Our expert testing identifies leakage paths, verifies containment performance, and ensures your facility delivers the airflow separation required for resilient, energy‑efficient IT operations.

Why Air Leakage Testing Matters in Modern Data Centres

Effective airflow containment is essential for:

  • Lower cooling energy consumption
  • Stable rack inlet temperatures
  • Reduced bypass airflow
  • Improved CRAH/CRAC efficiency

Poorly sealed COLO pods or HAC corridors can cause thermal instability, hot‑spot formation, and increased cooling costs. APT’s testing ensures your containment performs exactly as designed.

What We Test

  • COLO containment zones
  • HAC corridors
  • Pod‑based hot aisle systems
  • Return‑air plenums

Our testing covers both performance leakage and construction airtightness, giving operators a complete understanding of how well their containment is functioning.

The Three Types of Testing We Report

  1. 3% Leakage Rule – Performance Testing

We verify that HAC or COLO leakage is less than 3% of the design IT airflow, ensuring the containment performs correctly under real operating conditions.

This is the industry‑recognised benchmark for airflow separation in data centres.

  1. ATTMA Airtightness – Construction Quality

We measure leakage per square metre to assess the physical build quality of the containment system. This identifies issues such as:

  • Poorly sealed doors
  • Gaps around panels
  • Cable penetration failures

APT uses both metrics to ensure your containment is well‑built and performing correctly.

  1. High‑Pressure Integrity Testing for COLO & HAC Enclosures

In addition to operational air leakage testing, APT also performs high‑pressure integrity testing to verify the structural robustness of COLO pods and HAC corridors. This elevated‑pressure test (typically 75 Pa) is designed to expose weaknesses that only appear under stress conditions, such as:

  • Panel deflection
  • Door bowing
  • Seal failure
  • Roof‑panel movement
  • Plenum interaction issues

High‑pressure testing provides a deeper understanding of the mechanical stability of the enclosure, ensuring it can withstand abnormal airflow events, fan ramp‑ups.

Detailed Blower Door Smoke Air Leakage Surveys

APT also carries out specialist blower door smoke leakage surveys for COLOs and HAC corridors. This diagnostic testing combines high powered blower doors with controlled smoke release to visually identify exact leakage paths within the containment system.

Our smoke surveys reveal issues that standard airflow testing alone cannot show, including:

  • Leakage around containment doors and seals
  • Panel and roof‑section gaps
  • Cable‑tray and service penetrations
  • Underside leakage at floor interfaces
  • Plenum bypass routes
  • Hidden construction defects behind IT racks

Using positive pressure, we trace smoke movement through the enclosure to pinpoint weaknesses with photographic evidence. This allows contractors to carry out targeted remedial sealing, improving both airtightness quality and cooling performance.

APT’s blower door smoke surveys are widely used during commissioning, pre‑go‑live checks, and post‑remedial validation to ensure the containment is fully sealed, structurally robust, and performing at its designed efficiency.

Our Air Testing Process

  • Full ATTMA flow‑curve analysis
  • Leakage measurement at 7.5 Pa (operational pressure)
  • Optional stress testing at higher pressures
  • Smoke‑tracing diagnostics
  • Identification of leakage paths
  • Clear pass/fail criteria
  • Practical remediation recommendations

This gives you a complete, actionable understanding of your containment performance.

Benefits of Air Testing COLOs & HAC Corridors in Data Centres 

  • Reduced cooling energy consumption
  • Lower bypass airflow
  • Improved CRAH/CRAC efficiency
  • More stable rack inlet temperatures
  • Better resilience under redundancy conditions
  • Enhanced long‑term operational stability
  • Optimised airflow management for high‑density IT loads

APT’s testing helps data‑centre operators reduce costs, improve reliability, and maintain compliance with modern airflow standards.

Why Choose APT for Data Centre Air Testing?

APT specialises in data‑centre‑specific airtightness testing, combining building‑compliance expertise with deep knowledge of IT cooling behaviour. We deliver:

  • Clear, actionable reports
  • Accurate leakage measurements
  • Professional diagnostics
  • Contractor‑friendly recommendations
  • UK‑wide coverage including Poole, Dorset, London, Manchester & major data‑centre hubs

Our testing is trusted by COLO operators, M&E consultants, commissioning teams, and mission‑critical facility managers.

Get a Quote for COLO & HAC Air Testing

APT provides fast, reliable and highly accurate air leakage testing for COLOs and HAC corridors within Data Centres across the UK.