Failed Sound Testing in London?

Failed Sound Testing in London?

When a building fails the Part E Sound Test in London it may be down to a problem with the acoustic construction, this may be down to issues such as noise flanking etc.

Ongoing problems with airborne and structure borne sound are often associated with direct noise flanking transmission through floors and supporting walls and other associated structures such as the external envelope. One common cause of noise flanking and failed sound testing is often associated with the inclusion of lightweight blocks within the construction of the building envelope and/or blocked cavities. It all cases it is essential to establish if your problem is due to direct transmission, flanking transmission or a combination of both so that the most cost effective remedial treatment can be chosen.

Sound Testing in London

Unwanted noise travelling along flanking paths will make the building structure vibrate which causes the sound to radiate into your room. One simple cost effective solution is to build another wall or ceiling in front of the original, but not connected to it (often called an independent wall or ceiling) so it provides isolation between materials.

One way to reduce the chance of flanking transmission is through careful consideration to the design at the start of the project.  Unfortunately, by simply specifying high performance wall and floor partitions it is no guarantee to adequate sound isolation and successful sound insulation testing. APT Sound Testing offer both preconstruction and post construction design solutions to achieve a successful sound testing in-line with Part E of Building Regulations. We also offer onsite inspection services to ensure that the sound insulation elements are being installed as per manufactures guild-lines. Even if both types of sound are emitting through the ceiling/floor then there are some easy installations that should reduce the sound levels and improve your sound test results. By advising on a simple cost effective wall and/or floor upgrade, we are able to forward simple to follow acoustic design reviews, utilising our extensive knowledge of different materials and construction methods

If you have failed a sound test and need acoustic advice on how to overcome the problem then please contact us at info@aptsoundtesting.co.uk or call me direct on 07775623464.

SOUND INSULATION TESTING in LONDON

Sound Insulation Testing in London

APT Sound Testing have a massive amount of experience when it comes to undertaking  sound insulation testing in London. We have the necessary know how and onsite experience to carry out sound insulation testing on a new build or conversion project throughout London for a most competitive prices.

Our engineers carry out the airborne and impact sound test measurements in compliance with Part E of Building Regulations. We have previously undertaken hundreds of sound tests to new build and conversion projects. we also undertake detailed design reviews to ensure our clients achieve a successful sound test.

NoiseFlankingWall

Our engineers also understand the extra coordination that’s required to test within central London, whether its restricted access and/or parking we have it covered. Many other companies that are based outside London literally double their fees when undertaking sound testing in the capital; as we have an office in London we can afford to charge the same flat fee as we do across the rest of the UK.  Also as we are based in London we can usually arrive on site at the agreed time which often minimises delays to planned noisy works on site. We aim to arrive early and leave early.

We undertake London sound testing on all types of projects from simple flat conversions to large new apartment block developments containing many hundreds of flats. We also undertake sound testing where a lease holder dispute has arisen, which is quite common in London. We can undertake sample sound testing to highlight the existing sound insulation performance of the dividing wall and/or floor partitions to allow for targeted acoustic design to keep cost and delays to a minimum.

If you would like more information on our London Sound Insulation Testing package please contact us now at info@aptsoundtesting.co.uk or call me directly on 07775623464.

Acoustic Design Considerations

Acoustic Design Considerations

In our experience you need to take into account the acoustic design from the offset of the project, failing to do so usually results in sound test failure; if you do, it usually results in successful pre-completion testing in compliance with Building Regulations Part E.

In many cases, sound test failure can also be down to the poor workmanship rather than the actual design, that is why we offer a full acoustic design package which includes for site survey visits; that way we have the acoustic design and ongoing onsite construction covered, reducing the chance of sound test failure.

ACOUSTIC_DESIGN

There are many Design Considerations, here are a few of the most important:

  • Avoid the use of lightweight blocks in the inner envelope construction as sound will travel both vertically and horizontally from dwelling to dwelling.
  • The use of resilient suspended ceilings will help improve the performance of the floor partition.
  • Ensure all support steels/timbers are carefully boxed out where they travel from flat to flat vertically and horizontally.
  • Use a high quality resilient acoustic membrane on top of the floor to improve the impact performance of a floor.
  • Ensure all penetrations are fully sealed where they terminate through floors and they are adequately boxed with acoustic quilt and two layers of plasterboard.

For peace of mind, many of our clients choose our complete acoustic design package, which contains the following elements:

  • Site Survey Visits – to let us view the existing site construction.
  • Sample Sound Testing – of the existing construction. This offers an accurate overview of the acoustic performance of the existing partitions.
  • Acoustic Design Review – a full design review of the proposed party floors and walls.

If you have a project that’s needs acoustic design advice or sound testing in London, then please contact us at: info@aptsoundtesting.co.uk or phone us directly on 07775623464.

I Have Passed The Sound Testing So Why Do I Have Squeaking Floors

I Have Passed The Sound Testing So Why Do I Have Squeaking Floors

One potential problem with floors is that they can squeak after they have been installed. This is often down to the fact that Joists are often spaced too far apart which can result in a reduction in floor stiffness and complaints about footstep noise at low frequencies. Over-notching of joists can also lead to a reduction in floor stiffness and also potential squeaking. Although  the projects partitions may have passed impact sound tests, the annoying  squeaking sound may persist due to the extra loads imposed to the floor partition by people walking above.

Noise_Problems_Failed_Sound_Testing

To help with pass the impact sound test timber floors a resilient membrane is often incorporated into the overall floor design. This not only assists impact sound insulation (against footstep noise transference) but also reduces airborne sound transference.

Timber floating floors, must use a flanking strip to isolate the floorboards from the perimeter walls and skirting’s. If flanking strips are not fitted then footstep noise can easily enter the structure via walls etc. and subsequently flank into the adjacent dwellings. In the 1980s, mineral wool was used as a flanking strip but it was difficult to turn round at the floorboard edge. It was also prone to deterioration due to compression and movement under dynamic load. As a direct result of this, 5–10mm polyethylene flanking strips were incorporated into the acoustic design and construction, they are also easier to install and do not degrade over time to the same extent.

There are many reasons why floors may fail the sound testing, such as the use of incorrect mechanical fixing can reduce the insulation performance provided by floating floor treatments and resilient ceiling bars. Using very long screws will lead to bridging of the resilient layers and noise flanking. Inserting pipes or services within a platform floor can reduce the potential acoustic performance if they are not adequately boxed.  The placing pipes or cables under resilient battens can also bridge the resilient layer.

If you require more information about acoustic design and/or sound testing on your project,  please contact us now at info@aptsoundtesting.co.uk or call me direct 07775623464.

Careful Consideration to the Acoustic Design will help you pass your Sound Test

Careful Consideration to the Acoustic Design will help you pass your Sound Test

Careful consideration must be shown to the acoustic design from the start of every conversion project to avoid sound test failures. Most floor designs throughout the 1980s, encompassed the following construction details:

  • Floorboards (18–22mm thick)
  • Gypsum-based board
  • Mineral wool batt (80kg/m3)
  • Sub decking
  • 200-220mm joists
  • 100mm quilt insulation between the joists
  • One/Two layers of gypsum-based board for the ceiling

One the most common constructions used a combination of floorboard, gypsum board and mineral wool batt and was termed a “platform floor”. There is a wide range of batt densities. If the density is too low the floor surface is able to ‘bounce’ and deflect much more easily. If the density is too high then the floor may be too hard and impact sound is able to transmit more easily to the residential dwelling below resulting in sound test failure, so it was very difficult picking the correct materials.

ACOUSTIC_DESIGN

Often, even when resilient battens are used, continuous structural contact along the joist between the floor sub-deck and ceiling provides a strong path for sound transmission. If contact between the ceiling and the joists can be reduced, an increase in airborne and impact performance will be achieved.

One solution is to add another ceiling element to the overall construction. This can provide the extra isolation required to pass the sound testing in London.  This can be achieved by incorporate resilient metal bars which are connected to the underside of the joists and mounted perpendicular (90˚) to the joist direction. If plasterboard has already been tacked to the underside of the joists you can firstly add timber batten and then add the resilient bars, also mounted perpendicular (90˚ to the batten, thereafter 2 x 12.5mm layers of soundboard can be tacked to the underside of the resilient bar. Above the floor a resilient membrane can be used to reduce the chance of impact noise transmitting down to dwelling below.

If you require more information about acoustic design and/or sound testing on your project, please contact us now at info@aptsoundtesting.co.uk or call me direct on 07775623464.

The Different Types of Sound testing in London

This article explains the different types of Sound testing in London

There are two different types of sound testing you need to pass to comply with Building Regulations Part E. This article offers a brief description of both.

Airborne Sound Testing in London

The airborne performance requirements of Part E stipulate that new build properties ned to achieve 45dB and converted properties 43dB. This applies both to party walls and floors between properties. This level is the difference between the source level and the receiver level during London sound tests.

If the source level in one flat is 110dB and the receiver level in the neighbouring flat is 55dB, the level difference (or sound reduction performance) is 55dB. Thereafter the measurement is corrected for several factors such as background noise, room characteristics and frequency weighting, giving the final sound insulation performance value of the tested partition.

sound testing equipment

In this case the higher the number achieved the better the sound insulation performance, whereas Impact testing is the opposite, i.e. the lower the figure the better performance. The measurement is done by using a Norsonic Class 1 Analyser, Amplifier and Speaker (as shown below)

Impact Sound Testing In London

Impact sound testing only applies to party floors and related to the effectiveness of the floor construction in absorbing shock such as footfall noise. The measurement is done by using a Norsonic tapping machine (as shown below). The machine has 5 weights which tapping in regular succession on the tested floor which emulates footfall noise. The noise levels are taken in the receiving room below, which are then measured and averaged for different tapper positions, which then gives the sound reduction rating of the floor. In this case the lower the figure, the better the performance.

Impact Sound Testing

If you have a project that’s needs acoustic design advice or Sound Testing in London, then please contact us at: info@aptsoundtesting.co.uk or phone us directly on 07775623464.

Good Acoustic Design for Sound Testing In London

Good Acoustic Design to Help Pass your Sound Testing In London 

Careful acoustic design consideration should be used from the offset of the project to ensure your project passes the Sound Testing In London, whether it’s new built or a conversion project to meet the required requirements Building Regulations Part E. Tackling these two aspects involves different construction techniques and careful acoustic design detailing. This is good news for the new residents as it proves adequate levels of soundproofing have been incorporated into the buildings design and construction.

In many cases, sound test failure can also be down to the poor workmanship rather than the acoustic design, that is why we offer a full acoustic package which includes for site survey visits; that way we have the acoustic design and onsite construction covered, reducing the chance of sound test failure.

NoiseFlankingWall

We offer an acoustic design package, which contains the following elements:

  • Site Survey Visits – to let us view the existing site construction. This allows us to check for potential problematic construction such as inclusion of lightweight blocks in the existing construction. It also lets us check that the installation teams are installing the acoustic materials as per manufacturer’s guidelines.
  • Sample Sound Testing – of the existing construction. This offers an accurate overview of the acoustic performance of the existing partitions which enables us to offer a targeted acoustic design using the sound insulation performance of the existing construction.

Acoustic Design Considerations

  • Avoid the use of lightweight blocks in the inner envelope construction as sound will travel both vertically and horizontally from dwelling to dwelling.
  • The use of resilient suspended ceilings will help improve the performance of the floor partition.
  • Ensure all support steels/timbers are carefully boxed out where they travel from flat to flat vertically and horizontally.
  • Use a high quality resilient acoustic membrane on top of the floor to improve the impact performance of a floor.
  • Ensure all penetrations are fully sealed where they terminate through floors and they are adequately boxed with acoustic quilt and two layers of plasterboard.

If you have a project that’s needs acoustic design advice or sound testing in London, then please contact us at: info@aptsoundtesting.co.uk or phone us directly on 07775623464

How Many Sound Tests Do I Need On My Project

How Many Sound Tests Do I Need On My Project?

Our clients often ask ‘how many sound tests do I need on my project’. Part E stipulated that one set of sound tests needs to be undertaken for every ten flats or houses, provided the construction system is the same. A set means that the test should include two locations where the party element (wall or floor) is tested. This is equivalent to two individual tests when assessing the performance of a wall this means 2 airborne wall, 2 airborne floor and 2 impact sound tests as a minimum wherever possible. All tests must be undertaken between habitable spaces (e.g. bedrooms, living rooms) and not to or from common spaces such as stairwells and corridors.

Acoustic Design Advice

Approved Document E 2003 also states that a minimum of 10% of all party walls and floors is sound tested for every type of construction or sub-group, this means where there a variations in the construction of the floors and/or walls may occur then further testing may be required. The amount of sound tests required for each type of development is:

Houses:

On houses two airborne sound insulation tests on a pair of separating walls would be required.

Flats:

On flats a 6 Pack would normally be required, this would usually comprise of two airborne sound insulation tests on separating walls; two airborne sound insulation tests of separating floors and two impact sound transmission tests of separating floors

Rooms for Residential Purposes:

On student accommodation, hotel rooms & care homes a set of tests would usually comprise of one airborne sound insulation test of a separating wall; one airborne sound insulation test on a separating floor and one impact sound transmission test of a separating floor.

If you are unsure of the amount of sound tests required on your development, please contact us now at: info@aptsoundtesting.co.uk or call me direct on 07775623464.

Minimising Noise Flanking Transmission to Pass Sound Tests

Minimising Noise Flanking Transmission to Pass Sound Testing

One way to reduce the chance of noise flanking transmission/s to pass the sound testing for Part E of Building Regulations is to carefully look at the acoustic details at the design phase of the project, as well as good planning and workmanship thereafter. Unfortunately, by simply specifying high performance wall and floor partitions between dwellings is no guarantee to a sound isolation and subsequently successful sound testing.

Sound travels along the path of least resistance between rooms, usually through any penetrations/air leaks or through rigid and poorly isolated connections in the structure itself, these routes are called noise flanking paths.

  • Wide gaps below doors provide a flanking noise pathway.
  • Air leakage around partition walls at the wall/ceilings junction.
  • Sound leaking through ‘lightweight’ hollow-core doors.
  • Through ductwork penetrations between two rooms or boiler cupboards placed back to back.
  • Fixtures & Outlets – Light Switches, Telephone Outlets, and Recessed Lighting Fixtures (if penetrations have been cut back to back with the opposite dwelling under test)
  • Poor sound isolation between floors, if subfloor wooden planking extend beneath the dividing floor partition and into an  adjoining dwelling this will form a sound flanking pathway.
  • Framing connections that include solid framing members passing between building areas such as oak beams where large old houses have ben subdivided.
  • Poor isolation to partition abutments to adjoining walls, ceilings, floors
  • Service penetrations behind back to back kitchens, such as soil stacks, waste and recessed pipework.
  • Plumbing Chases – Junctures Between the Walls & Floor Slab Above or at the Exterior Wall Juncture (this should be filed with mortar etc. to add mass to this weakened area)
  • Through Structural Steel (structural steel beams are often a major cause of noise transmission as plasterboard is often fixed directly to the steel without sound breaks)
  • Dividing Floors – Through Floor and Floor Joist Space (if insulation has not been installed or direct fixing to joists without a drop ceiling below the partition under test)
  • Dividing Ceilings – Above and Through the Ceiling Space (where an adequate acoustic break has not been carried on through the ceiling void).
  • Recessed light fixtures that pass through the plasterboard and acoustic insulation.
  • The wrong fixings used during the installation of resilient channel systems, i.e. drywall screws that are too long that penetrate into the ceiling joists.
  • Window noise transmission due to poor performance glass etc.
  • Door noise transmission due to the inclusion of lightweight hollow core doors, with large gaps to the bottom of the door threshold.
  • On bathroom partitions, install drywall all the way to the floor before installing the bath and seal all plumbing penetrations through walls with a flexible sealant.

NoiseFlankingWall

If the wall/floor partitions have poor isolation and can greatly reduce the effectiveness of soundproofing efforts and can lead to sound test failures. Even if your construction allows for ‘robust’ sound insulation ratings, it will be rendered useless, if sound can pass easily through service penetrations in the walls and floors or through lightweight doors.

APT Sound Testing offers both pre & post construction design solutions to achieve the required sound isolation requirements of Part E of Building Regulations.

We offer an acoustic onsite inspection service to ensure that the sound insulation elements are being installed as per manufactures guide lines and the quality of the workmanship is consistent with ‘best practice’ noise control procedures and we have the technical experience to help identify and rectify your soundproofing or noise flanking problem/s.

If you would like more information in regards to sound testing, please contact us at: info@aptsoundtesting.co.uk or call us direct on 07775623464

Should I inform my Neighbours of the Sound Testing?

Should I inform my Neighbours of the Sound Testing?

Your neighbours will need to be contacted if access is required to their properties to complete the sound testing. Also as the sound levels produced during the test are very high it would be ‘neighbourly’ to inform the residents as they are likely to hear the test. If your project is a new build and/or a change of use and its built onto an existing property then chances are you will be required to undertake an airborne wall test. We recommend that you check this with your local building control officer prior to the testing so you can plan access to the neighbouring properties accordingly.
Can I Observe the Sound Testing?

sound testing equipment

APT Sound Testing will happily give you a brief demonstration and overview of the test, if so required; however, during the actual sound testing, we will need to follow stringent rules which restrict extra personnel within the test areas.
I want peace of mind that I’ll pass the sound testing

Poor Sound test results can occur for many reasons. The most common factor influencing acoustic performance is poor workmanship. Detailing is critical to maximising on site acoustic performance, especially in floor and wall isolation and appropriate party wall and floor construction. If inadequate provision for the isolation of materials is not undertaken

Should I inform my Neighbours of the Sound Testing?