Good Acoustic Design

Good Acoustic Design to Pass Your Sound Insulation Testing

We have carried our hundreds of acoustic design reviews and sound insulation tests, so we are well placed to help you overcome any potential problems to achieve compliance with Building Regulations Part E.

It is essential that good acoustic design is actioned from the offset of any new construction project. When designing acoustic partitions you will need to consider the following

architect drafting a house blueprint

  1. The careful design of floor plans to avoid habitual rooms being placed side by side.
  2. The mass and density of products that you are using.
  3. Using good design detailing to ensure the careful isolation of materials.
  4. The whole construction detail and how it is made up.
  5. Undertaking careful acoustic detailing of junctions between walls, ceilings and floors.
  6. Using acoustic wall ties in cavity walls.
  7. Types of doors in sound resisting walls.
  8. Containment of noise within noisy parts of a building such as lift shafts.
  9. Positions of sockets and flues on opposite sides of walls to ensure they don’t sit back to back.
  10. Sealing and filling of joints.
  11. The use of cavity closer’s on window/door reveals.
  12. Careful sealing of service penetrations.
  13. Designing to reduce potential reverberation in common parts of buildings such as corridors and entrance areas and the subsequent use of absorbent materials.

Unfortunately unless the acoustic design has been taken into account, the floor and ceiling partitions can be the main pathways for sound transmission.  The first type of sound transmission is airborne sound such as TV and speech; and the second is the passage of impact sounds such as footfall or children’s toys being dropped on the floor above.  Achieving good airborne and impact sound isolation requires careful acoustic design considerations.

APT Sound Testing can advise on all types of acoustic design, whether it’s accomplished during initial construction or during a refurbishment/renovation project. We also undertake UKAS accredited sound testing providing a ‘one stop’ solution for all your acoustic requirements.

If you would like more information in regards to good acoustic design and/or sound testing please follow our blog at: http://soundtestinguk.blogspot.co.uk or contact us at: info@aptsoundtesting.co.uk and 07775623464 or visit our website at: www.aptsoundtesting.co.uk

 

Sound Insulation Testing in London

Sound Insulation Testing in London

Unless plans were fully approved prior to 1 July 2003, sound insulation testing will be required on your London development between rooms or spaces that share a common area of separating wall and/or floor as stipulated in Building Regulations Part E for the passage of sound. Sound insulation Testing is not generally required for internal walls and floors within a dwelling-house, flat or room for residential purposes; however all internal partitions should be designed to achieve 40dB.

The buildings that require sound testing are:

  1. Dwelling-houses, flats or rooms for residential purposes created by conversion of existing buildings or new build rooms for residential purposes will need to be tested if work starts after 1 July 2004.
  2. New build dwelling-houses and flats will need to be tested if work starts after 1 July 2004.

The main aim of Sound testing in London is to ensure that minimum standards of sound resistance have not been compromised by poor workmanship and/or poor design. You are normally required to undertake sound testing to each type of construction, i.e. if you have a mixture of brick, blockwork, timber and metal studwork walls all four types would need to be tested, followed by a 10% sample of that type using the equipment shown in Plate A below.

Plate A – Our Sound Test Equipment.

sound testing equipment

For instance, if you have a project with 25 flats you would be required to do 3 x 6 pack of tests; each 6 pack contains 2 airborne wall, 2 airborne floor and 2 impact sound tests; however if any test failures occur, then the number of sound tests may need to increase on the development. When sound test failures occur, then the design and construction of the failed partitions will need to be revisited to try and evaluate the reasons for the failure; thereafter, agreement can be reached on how to rectify problem.

APT Sound Testing can advise on all types of acoustic design, whether it’s accomplished during initial construction or during a refurbishment/renovation project. We also undertake UKAS accredited sound testing providing a ‘one stop’ solution for all your acoustic requirements.

If you would like more information in regards to sound insulation testing please follow our blog at: http://soundtestinguk.blogspot.co.uk or contact us at: info@aptsoundtesting.co.uk and 07775623464 or visit our website at: www.aptsoundtesting.co.uk

Noise Damping to Improve Sound Testing

Noise Damping to Improve Sound Testing 

Noise damping is the most efficient and effective ways to control vibration and noise radiation at the source. Damping materials lessen this noise by turning the vibration into a low-grade heat. By using viscoelastic materials, it changes the resonant frequency of a substrate. By combining vibration damping materials and sound absorbers a composite acoustic construction can be achieved, that can control both airborne and structure borne noise – the final element for good soundproofing.

acoustic_wall_upgrade

It is worth noting that a  large number of manufacturers now produce a wide range of systems designed to improve sound insulation in homes and commercial buildings. In all instances, the effectiveness of these materials will vary depending on the situation in which they are installed. When choosing the acoustic product/s, detailed information on the likely sound insulation performance should be requested from the supplier. If you have an existing property you should check the existing construction of the dividing wall/floor partitions and work back from there. You are advised to give careful consideration to the data supplied by a manufacturer before using a proprietary product. it is also worth noting that the sound insulation value/s given for each product will be ‘best case’ as they have been tested in laboratory conditions and not on site – this is usually worse result by up to 3-5 dB) which may be the difference between a sound test pass or failure.

acoustic_floor_roll_

Also when undertaking remedial work to improve the sound insulation, the acoustic materials are often quite heavy which may result in considerable weight being added to the structure of a property. Thus it is essential to check that the ceiling or floor joists can carry the increased loads satisfactorily.

So in a nutshell if you allow for the following four main elements of sound insulation on your acoustic partition design; Decoupling, Absorption, Mass and Damping, your development should pass the sound insulation test at the first attempt.

If you would like more information in regards to acoustic design and sound insulation testing, please contact us now at info@aptsoundtesting.co.uk or call Darren direct on 07775623464.

Adding Mass to Improve Sound Insulation

Adding Mass to Improve Sound Insulation

Adding mass to improve sound insulation can be one of the most important elements to improving precompletion sound testing results. In summary it basically means you add extra weight/mass to the construction of the acoustic wall and/or floor partition. Materials such as solid block-work masonry is best for wall construction; however it is very important that the block-work envelope is constructed out of solid concrete block work as the use of lightweight block work often ends in sound test failure.

Sound_Insulation_Test_London

 For floor construction, solid concrete floors – min 150mm) are usually the best construction for outright mass; however soundboard, plywood and OSB can be found fairly cheaply and will also do the job – if installed as per manufacturer’s guidelines. It is very important that adequate site supervision is on hand to check the construction of all acoustic partitions.

It is basic physics, so for sound to conduct through a wall, it has to actually move (vibrate) the wall ever so slightly. As a heavier wall is harder to move than a lighter wall then it should vibrate less and turn let through less noise. Soundboard is one of the lowest cost sources of mass available and also one of the most commonly used. Wherever possible its best to use two layers of 12.5mm board with the correct laps to the boards. Although the wall will still vibrate it will be less due to the extra mass.

It’s worth noting that although the added mass improved things and it will be more difficult for sound to move this heavier wall, in many instances you will still hear low frequencies (bass noise) quite easily.

Our next blog covers the last – but not least) element of acoustic design – Damping. If you would like more information in regards to acoustic design and sound insulation testing, please contact us now at info@aptsoundtesting.co.uk or call Darren direct on 07775623464.

Noise Problems in Refurbished Industrial Buildings

Noise Problems in Refurbished Industrial Buildings

We often get asked to undertake a series of sound test measurements to establish the acoustic performance of the wall of floors construction in existing buildings where the dwelling owners are concerned about excess noise.

In recent years the refurbishment of old industrial buildings into residential dwellings has become a very popular. Frequently the existing finishes of existing concrete, brick or wood Noise Problems in Refurbished Industrial Buildingsare left as the interior finish, supposedly to provide the “loft” type of décor. Such designs require even more acoustic design attention if sound privacy is to be achieved. Potential noise problems in refurbished industrial buildings can be quite challenging so buyers should insist that actual on-site sound insulation testing is undertaken to check the building has complied with the sound design performance criteria of Building Regulations Part E.

sound_transmission_through_floors

If you think you have a sound problem in your dwelling and are seeking help to resolve the problem, be sure to contact us and describe the problem in as much detail as possible. Describe the nature of the sounds, when and where you can hear it. Is it impact noise or airborne noise or a combination of both? If the unit is of recent construction you may need to procure a set of architectural drawings and mark-up which partitions noisiest. The more information you can provide us, the quicker we can try to determine the nature of the problem and subsequently find an acoustic solution for the partition/s.

We can also visit site and undertake sample testing on the dividing partitions. If the partitions fail the tests we can identify the main reasons for the sound test failures so targeted remedial treatments can be undertaken.

If you have a project that requires acoustic design advice or sound insulation testing, then please contact us at: info@aptsoundtesting.co.uk or phone me directly on 07775623464.

 

Reducing Noise in Residential Buildings

Reducing Noise in Residential Buildings

We often get asked how noise can be reduced in residential buildings such as apartments or terrace houses. One of the most common problems is noise transmission through the floor and ceiling assemblies in flats and through the wall partitions in houses. The usual noise problems range from airborne noise transmission from voices TVs and music to footfall impact noise caused by high heels on wooden/tiled floors.

Noise_Problems_Failed_Sound_Testing

In most cases for newer residential units many of the problems could have been prevented in the first place, if more attention had been paid to noise control during the design and construction process.   If the acoustic design has not been taken into account from the off-set of the project, then it becomes far more problematic and costly if noise problems are discovered and the partitions fail the sound insulation testing during the per-completion testing.

If you are contemplating the purchase of a unit, do not be afraid to question the contractor and the real estate agents about the sound insulation results for the unit. Ask if any of the units failed during the precompletion testing. In some cases just because a sample of the units had been tested during prior to handover doesn’t mean unit has been sound tested.

If you are not happy with the sound insulation properties of your unit then you may have a case to demand corrective action at the expense of others. If you have a noise problem that is not resolved and you go to sell your unit, you may be compelled to reveal the deficiency to a prospective buyer which may have an impact on the selling price.

If you need acoustic advice on your project, please don’t hesitate to contact us no at: info@aptsoundtesting.co.uk or call me direct on 07775623464.

Our Sound Testing Procedure

Our Sound Testing Procedure

Our sound testing procedure is quite simple and our acoustic engineer will be happy to explain this on site. Essentially, for party walls there is one type of sound insulation test which is airborne sound test and for compartment floors there are two types of sound insulation tests which are airborne and impact sound insulation tests. The airborne sound insulation test is carried out by means of a loudspeaker emitting a steady source of noise on one side of the partition (wall or floor) to be measured. The corresponding sound level is measured on the other side of the partition.

sound testing equipment

Impact sound insulation tests are carried out by means of a tapping machine placed on the floor sample to be measured and the noise measured in the room or space below. Calculations are done based on these measurement and the above mentioned parameters are calculated and compared to the Building Regulations Part E sound insulation requirements for the given type of the building. It is important that the building to be sound tested is completely finished and sealed with no sound leakage through doors and windows.  Please see our check list for sound insulation testing for more information.

The airborne and impact sound insulation tests carried out in full accordance with the measurement procedures of BS EN ISO 140-4:1998[3] for field measurements with a single figure DnTw and LnTw in accordance with BS EN ISO 717. As per the new regulations the Spectrum Adaptation Ctr which is a correction factor calculated from the measured DnT.w and the corresponding third octave band DnT values.  It uses a set of weighting levels in third octave bands derived from a road traffic noise spectrum.  It is applied to airborne test results and is measured in dB.

If you would like advice on your acoustic design or sound testing in London, please contact us now at info@aptsoundtesting.co.uk or call us on 07775623464

Simple Acoustic Floor and Wall Upgrades

Simple Acoustic Floor and Wall Upgrades 

There are many quick and simple acoustic wall and floor upgrades to help you achieve compliance with Build Regulations Part E. One of the easiest wall solutions is to install a 70mm met-sec partition in front of the existing wall abutting dwellings. Firstly leave approx. 25mm gap between the back of the met-sec and the existing wall. Then install 50mm acoustic wool to the inside of the met-sec and add two layers of soundboard to the outside of the met-sec frame, ensuring all boards are properly lapped and ensure the perimeter joints are kept back from the surrounding construction and filled with acoustic mastic. Also make sure that all sockets etc. are placed in a different position to the sockets on the other side of the wall to prevent noise transference.

Acoustic_Ceiling_Upgrade

To reduce airborne and impact sound transmission through the floor, one simple solution is to add a timber baton to the bottom of the joists. Then add an acoustic resilient hanger. To the inside of the newly formed void add an AW 25 Isowool acoustic insulation. To the underside of the hangers install 2 x 12.5mm layers of soundboard. Allow for the correct laps in the plasterboard and and ensure the perimeter joints are kept back from the surrounding wall construction. Add AW100 Isowool to the centre joist void and to the top of the joists install 18mm flooring. To the top of the flooring add a 4mm resilient matt.

The above Air and Wall solutions should help your project comply with Approved Document E for Sound Testing in London. If you have a project that’s needs acoustic design advice or needs sound insulation testing then please contact us at: info@aptsoundtesting.co.uk and we should be able to offer you an expedient acoustic solution to help you achieve practical completion.

Noise Flanking Can Lead to Sound Test Failure

Noise Flanking Can Lead to Sound Test Failure

Noise flanking can be a huge problem and one of the main causes of excessive sound transmission. If your project fails the sound testing, more often than not noise flanking will be the culprit.

To get an understanding for why the acoustic partitions are performing poorly a detailed diagnosis and invasive investigation, such as the removal of some of the wall and floor partitions will usually need to take place. In many cases a large amount of noise flanking is due to serious design faults such as the use of lightweight blocks in the construction of the walls in an apartment development, this allows the sound to travel along the walls and floors from dwelling to dwelling. In many cases a wall and/or floor partition may have a very good acoustic design and construction; however the partition will still fail as the sound is travelling along a noise flanking path.

Sound_Insulation_Test_London

We often get asked what ate the main reasons noise flanking on new and existing dwellings, in our experience they are:

  1. Where lightweight blocks used in the inner envelope construction. This allows sound to travel along the lightweight blocks both vertically and horizontally from dwelling to dwelling.
  2. Through dividing floors if there is lack of mass or acoustic insulation has not been installed and/or or direct fixing of plasterboard and/or floorboards to joists without using a resilient ceiling construction and/or floating floor.
  3. Through Windows if they are no double glazed or have secondary glazing as a minimum
  4. Through Fixtures & fittings such as light switches, telephone outlets and TV cable ducts where they sit back to back against the adjoining property.
  5. Along structural joints along the perimeter wall and floor joint. These areas should be filled with acoustic mastic)
  6. Structural steels that run through one property to the other without material isolation, i.e. plasterboard is screwed directly to the steel offering little or no noise isolation.

There are many quick and simple solutions to improve the acoustic performance of dividing wall partitions. One of the easiest wall solutions is to install a met-sec partition in front of dividing partition.

If you have a project that’s needs acoustic design advice or needs sound insulation testing then please contact us at: info@aptsoundtesting.co.uk. We should be able to offer you an expedient acoustic solution to help you achieve practical completion.

SOUND TESTING FOR LONDON

SOUND TESTING FOR LONDON

London is a massive city containing in excess of 5 million dwellings, many sharing wall and floor partitions. In this noisy environment it is essential that good acoustic design and construction is incorporated into all new and refurbishment projects along with sound testing for London.

To try and help enforce good acoustic design principles, pre-completion sound testing was introduced in July 2003 to comply with new Approved Document E. The new building regulations required 10% of each party wall/floor construction type to be sound tested on all new build and conversion properties.

We have undertaken thousands of sound tests on converted properties in London and in our experience if the partitions haven’t received any acoustic upgrades the wall and floor partitions – as per the plate below) normally achieve approx. 30-35dB for airborne sound and 68-74dB for Impact Sound. Obviously these figures fall well short of the required 43dB & 64dB as stipulated in Approved Document E. Also, it’s worth taking into account that sound doubles every 10dB, so 30-35dB for airborne sound and 68-74dB for impact sound would be massive failures and careful acoustic design and construction upgrades would be required.

Detail 1: Existing Floor Partitions (rated at approx. 30-35dB)

Failed_sound_Testing_Due_to_existing_floor_Construction_

Using our many years’ experience in building acoustics, we are able to offer a total design and testing solutions for new and conversion projects. We help many architects and top 10 construction companies with their acoustic design requirements from the largest developments containing hundreds of units through a pair of semi-detached dwellings. We always endeavour to find the best solution, always taking build-ability and cost into consideration.

If it’s a conversion project and you are unsure of the floor/wall construction, we often recommend our ‘sample sound testing service. Firstly, we visit site and undertake sample sound testing to at least one floor and wall partition, is consists of at least one airborne and impact test to the proposed dividing floor and an airborne test to the dividing wall. Once the sound test results are established we can then offer a targeted acoustic design solution to achieve a successful sound test in London in compliance with Approve Document E.

Whatever the problem we can usually find an acoustic solution that will help you achieve Building Regulation compliance  If you have a project that’s needs acoustic design advice or needs sound insulation testing then please contact us at: info@aptsoundtesting.co.uk