I Have Passed The Sound Testing So Why Do I Have Squeaking Floors

I Have Passed The Sound Testing So Why Do I Have Squeaking Floors

One potential problem with floors is that they can squeak after they have been installed. This is often down to the fact that Joists are often spaced too far apart which can result in a reduction in floor stiffness and complaints about footstep noise at low frequencies. Over-notching of joists can also lead to a reduction in floor stiffness and also potential squeaking. Although  the projects partitions may have passed impact sound tests, the annoying  squeaking sound may persist due to the extra loads imposed to the floor partition by people walking above.

Noise_Problems_Failed_Sound_Testing

To help with pass the impact sound test timber floors a resilient membrane is often incorporated into the overall floor design. This not only assists impact sound insulation (against footstep noise transference) but also reduces airborne sound transference.

Timber floating floors, must use a flanking strip to isolate the floorboards from the perimeter walls and skirting’s. If flanking strips are not fitted then footstep noise can easily enter the structure via walls etc. and subsequently flank into the adjacent dwellings. In the 1980s, mineral wool was used as a flanking strip but it was difficult to turn round at the floorboard edge. It was also prone to deterioration due to compression and movement under dynamic load. As a direct result of this, 5–10mm polyethylene flanking strips were incorporated into the acoustic design and construction, they are also easier to install and do not degrade over time to the same extent.

There are many reasons why floors may fail the sound testing, such as the use of incorrect mechanical fixing can reduce the insulation performance provided by floating floor treatments and resilient ceiling bars. Using very long screws will lead to bridging of the resilient layers and noise flanking. Inserting pipes or services within a platform floor can reduce the potential acoustic performance if they are not adequately boxed.  The placing pipes or cables under resilient battens can also bridge the resilient layer.

If you require more information about acoustic design and/or sound testing on your project,  please contact us now at info@aptsoundtesting.co.uk or call me direct 07775623464.

Careful Consideration to the Acoustic Design will help you pass your Sound Test

Careful Consideration to the Acoustic Design will help you pass your Sound Test

Careful consideration must be shown to the acoustic design from the start of every conversion project to avoid sound test failures. Most floor designs throughout the 1980s, encompassed the following construction details:

  • Floorboards (18–22mm thick)
  • Gypsum-based board
  • Mineral wool batt (80kg/m3)
  • Sub decking
  • 200-220mm joists
  • 100mm quilt insulation between the joists
  • One/Two layers of gypsum-based board for the ceiling

One the most common constructions used a combination of floorboard, gypsum board and mineral wool batt and was termed a “platform floor”. There is a wide range of batt densities. If the density is too low the floor surface is able to ‘bounce’ and deflect much more easily. If the density is too high then the floor may be too hard and impact sound is able to transmit more easily to the residential dwelling below resulting in sound test failure, so it was very difficult picking the correct materials.

ACOUSTIC_DESIGN

Often, even when resilient battens are used, continuous structural contact along the joist between the floor sub-deck and ceiling provides a strong path for sound transmission. If contact between the ceiling and the joists can be reduced, an increase in airborne and impact performance will be achieved.

One solution is to add another ceiling element to the overall construction. This can provide the extra isolation required to pass the sound testing in London.  This can be achieved by incorporate resilient metal bars which are connected to the underside of the joists and mounted perpendicular (90˚) to the joist direction. If plasterboard has already been tacked to the underside of the joists you can firstly add timber batten and then add the resilient bars, also mounted perpendicular (90˚ to the batten, thereafter 2 x 12.5mm layers of soundboard can be tacked to the underside of the resilient bar. Above the floor a resilient membrane can be used to reduce the chance of impact noise transmitting down to dwelling below.

If you require more information about acoustic design and/or sound testing on your project, please contact us now at info@aptsoundtesting.co.uk or call me direct on 07775623464.

The Different Types of Sound testing in London

This article explains the different types of Sound testing in London

There are two different types of sound testing you need to pass to comply with Building Regulations Part E. This article offers a brief description of both.

Airborne Sound Testing in London

The airborne performance requirements of Part E stipulate that new build properties ned to achieve 45dB and converted properties 43dB. This applies both to party walls and floors between properties. This level is the difference between the source level and the receiver level during London sound tests.

If the source level in one flat is 110dB and the receiver level in the neighbouring flat is 55dB, the level difference (or sound reduction performance) is 55dB. Thereafter the measurement is corrected for several factors such as background noise, room characteristics and frequency weighting, giving the final sound insulation performance value of the tested partition.

sound testing equipment

In this case the higher the number achieved the better the sound insulation performance, whereas Impact testing is the opposite, i.e. the lower the figure the better performance. The measurement is done by using a Norsonic Class 1 Analyser, Amplifier and Speaker (as shown below)

Impact Sound Testing In London

Impact sound testing only applies to party floors and related to the effectiveness of the floor construction in absorbing shock such as footfall noise. The measurement is done by using a Norsonic tapping machine (as shown below). The machine has 5 weights which tapping in regular succession on the tested floor which emulates footfall noise. The noise levels are taken in the receiving room below, which are then measured and averaged for different tapper positions, which then gives the sound reduction rating of the floor. In this case the lower the figure, the better the performance.

Impact Sound Testing

If you have a project that’s needs acoustic design advice or Sound Testing in London, then please contact us at: info@aptsoundtesting.co.uk or phone us directly on 07775623464.

Good Acoustic Design for Sound Testing In London

Good Acoustic Design to Help Pass your Sound Testing In London 

Careful acoustic design consideration should be used from the offset of the project to ensure your project passes the Sound Testing In London, whether it’s new built or a conversion project to meet the required requirements Building Regulations Part E. Tackling these two aspects involves different construction techniques and careful acoustic design detailing. This is good news for the new residents as it proves adequate levels of soundproofing have been incorporated into the buildings design and construction.

In many cases, sound test failure can also be down to the poor workmanship rather than the acoustic design, that is why we offer a full acoustic package which includes for site survey visits; that way we have the acoustic design and onsite construction covered, reducing the chance of sound test failure.

NoiseFlankingWall

We offer an acoustic design package, which contains the following elements:

  • Site Survey Visits – to let us view the existing site construction. This allows us to check for potential problematic construction such as inclusion of lightweight blocks in the existing construction. It also lets us check that the installation teams are installing the acoustic materials as per manufacturer’s guidelines.
  • Sample Sound Testing – of the existing construction. This offers an accurate overview of the acoustic performance of the existing partitions which enables us to offer a targeted acoustic design using the sound insulation performance of the existing construction.

Acoustic Design Considerations

  • Avoid the use of lightweight blocks in the inner envelope construction as sound will travel both vertically and horizontally from dwelling to dwelling.
  • The use of resilient suspended ceilings will help improve the performance of the floor partition.
  • Ensure all support steels/timbers are carefully boxed out where they travel from flat to flat vertically and horizontally.
  • Use a high quality resilient acoustic membrane on top of the floor to improve the impact performance of a floor.
  • Ensure all penetrations are fully sealed where they terminate through floors and they are adequately boxed with acoustic quilt and two layers of plasterboard.

If you have a project that’s needs acoustic design advice or sound testing in London, then please contact us at: info@aptsoundtesting.co.uk or phone us directly on 07775623464

APT SOUND TESTING – AN OVERVIEW OF OUR SERVICES

APT SOUND TESTING – AN OVERVIEW OF OUR SERVICES

We are often asked what types of sound test and noise surveys we can undertake. We offer all types of Sound Testing and noise surveys as well as design consultancy. Here is a quick summary of our acoustic services:

We are accredited to carry out Sound Insulation testing for:

  • Houses and flats in compliance with Part E of the Building Regulations.
  • Houses & Flats in compliance with the Code for Sustainable Homes.
  • All commercial buildings in compliance with BREEAM.
  • Classrooms within schools in compliance with BB93.

sound testing

We also try to provide a ‘one stop’ testing service for compliance with the latest Building Regulations. Our full ranges of services are:

Air Tightness Testing

  • Pre-completion Air Tightness Testing for residential and commercial buildings (Part L1&L2)
  • Air Tightness Design Reviews.
  • Combined Pre-completion Air & Sound Test (Part L1 & E) improves coordination and saves cost!

Sound Insulation Testing

  • Pre-completion Sound Testing for residential and school buildings (Part E & BB93)
  • Acoustic Design Consultancy (Part E & BB93)

Noise Surveys

  • Noise Surveys for planning (PPG24)
  • Noise Surveys for proposed air conditioning and other noise sources (BS4142)

Thermal Surveys

  • BREEAM Thermal surveys to show continuation of Insulation (Part L)
  • To locate leaks within roofs/walls and under floor heating. (Fault Diagnosis)
  • Annual Infrared Surveys on Electrical Switchboards and plant (Annual Maintenance)

Energy performance Certifications

  • Design Stage SAP & SBEM Certification (Part L)
  • As Built SAP & SBEM Certification (Part L)
  • Energy Performance Certificates (Part L)

Ventilation Testing

  • Ventilation Testing – now mandatory on all domestic ventilation systems (Part F)

Integrity Testing On Server Rooms

  • Integrity Testing on Server Rooms (rooms that have gaseous fire suppressant systems) – These must be carried out annually (ISO 15004)

UAV Aerial Surveys (unmanned)

  • Roof condition surveys on Residential, Factory and Church Roofs.
  • Thermal Surveys of Large Roofs.
  • Progress photos of large construction sites; i.e. at greenfield, foundations, envelope & completion stage.
  • Photos of completed dwellings and buildings for advertising purposes.
  • The Creation of 3D models of your project/site.

If you would like more information in regards to our sound insulation testing and/or air tightness testing packages, please don’t hesitate to contact us at: info@aptsoundtesting.co.uk or call Darren direct on 07775623464