The different types of Sound Testing

The different types of Sound Testing.

There are two distinct types of noise to consider through floors, they are:

  • Airborne Noise (for example speech and music) and
  • Impact Noise (for example footsteps directly on the floor above)

To take this into account there are two different types of Sound Testing required in compliance with Approved Document Part E. Even if both types of sound are emitting through the ceiling/floor then there are some easy installations that should reduce the sound levels and improve your sound test results.

sound testing equipment

To help our clients overcome this problem, we also offer our acoustic design service which helps clients to pass the sound testing upon completion of the acoustic upgrade. By advising on a simple cost effective wall and/or floor upgrade, we are able to forward simple to follow acoustic design reviews, utilising our extensive knowledge of different materials and construction methods. Using this philosophy, to date, we have had no sound test failures where our acoustic upgrades have been incorporated into the site construction, ensuring compliance with Part E of Building Regulations.

Pre-completion sound testing has been a mandatory requirement since July 2003 and all new build properties and conversions which were built after this date require 10% of each party wall/floor construction type to be tested. The Sound testing is to be carried out between pairs of rooms separated by party walls and/or floors. Part E stipulates that it sound testing should take place between dividing partitions between living rooms and bedrooms as these are classed as the two main habitable rooms; however, other rooms can be used if this is not possible such as dining rooms, kitchen and studies.

APT Sound Testing can undertake UKAS accredited Part E sound testing throughout England and Wales. Our sound test engineers carry all the latest class 1 acoustic equipment and we provide full UKAS accredited air and sound testing, so our clients can be sure that all testing is completed to the strictest  ISO quality controlled standards.

If you would like advice on your acoustic design or sound testing in London, please contact us now at info@aptsoundtesting.co.uk or call us on 07775623464

Simple Design Solutions to Pass Part E Sound Testing

Simple Design Solutions to Pass Part E Sound Testing

There are many simple solutions to reduce the noise levels and achieve compliance with Part E sound testing. We can provide easy to follow acoustic design reviews, utilising our extensive knowledge of different materials and construction methods.

Our clients often convert large houses into multiple flats, i.e. a flat on each of the ground, 1st and 2nd floors. They usually leave the floor boards in place and install a layer of plasterboard to the underside of the existing plasterboard/lathe and plaster. Unfortunately this simple type of upgrade usually achieves 30dB for airborne sound, which will result in sound testing failure. The sound test result needs to be 43db and above for airborne noise and 70dB for Impact sound.

Failed_sound_Testing_Due_to_existing_floor_Construction_

One simple solution to overcome the above problem would be to add another ceiling element to the overall construction. This can be achieved by incorporating resilient metal bars which are connected to the underside of the joists and mounted perpendicular (90˚) to the joist direction. If plasterboard has already been tacked to the underside of the joists you can firstly add timber batten and then add the resilient bars, also mounted perpendicular (90˚ to the batten, thereafter 2 x 12.5mm layers of soundboard can be tacked to the underside of the resilient bar and an acoustic insulation added to the newly formed void. In between the joist void add 100mm acoustic insulation. Above the floor boards add an acoustic resilient membrane to lower the chance of impact noise transmitting down to dwelling below.

Acoustic_Ceiling_Upgrade

The aforementioned acoustic design solution will usually result in successful sound testing and compliance with Approved Document Part E.

If you require more information in regards to sound testing and/or acoustic design on your project please visit our site at www.aptsoundtesting.co.uk or contact us at info@aptsoundtesting.co.uk, or call me direct on 07775623464.

Poor Acoustic Design

Poor Acoustic Design 

Sound test failure is often down to poor acoustic design detailing during the design and construction phase of a project.

Sound test failure are often associated with poor acoustic design which allows noise flanking transmission through dividing floor and wall partitions. Unwanted noise travelling along flanking paths can make the building structure vibrate which causes the sound to radiate into your room. One simple cost effective solution is to build another wall or ceiling in front of the original, to offer extra isolation. For this upgrade to work you need to make sure that the independent wall or ceiling is not directly connected to the existing failed partition; so it provides isolation between materials.

ACOUSTIC_DESIGN

One of the main reasons for excessive noise flanking down to the use of lightweight blocks in the construction of the wall construction. Due to the lightweight mas of the inner wall it allows sound to transmit from dwelling to another, both vertically and horizontally. If a building has failed its sound testing, it is essential to establish if the problem is due to direct transmission, flanking transmission or a combination of both so that the most cost and time effective remedial treatment can be designed and applied to the failed partitions.

One way to reduce the chance of sound testing failures due to excessive noise flanking transmission is through a careful consideration to the acoustic design at the start of the project.  Unfortunately, by simply specifying high performance wall and floor partitions, it is no guarantee to adequate sound isolation and successful sound testing.

APT offer preconstruction design advice to help you achieve successful sound testing in London in-line with Building Regulations Part E. We also offer onsite inspection services to ensure that the sound insulation elements are being installed as per manufactures guild-lines, as its not use having a robust design if it not being installed properly on site.

If you require more information in regards to sound testing and/or acoustic design on your project please visit our site at www.aptsoundtesting.co.uk or contact us at info@aptsoundtesting.co.uk, or call me direct on 07775623464.

Noise Flanking Through Steel Columns

Noise Flanking Through Steel Columns.

Unless Steel Columns or beams are isolated from the surrounding wall/floor partition it can lead to noise flanking, particular hollow steel columns. Steel can also provide a strong path for structural impact transmission due to its dense nature.

Pre-conversion sample sound tests should be able to identify whether any columns act as a significant transmission path and whether any acoustic treatment is required to remedy the situation. It may not be necessary to treat the column in all dwellings if flanking is limited, however in many instances the columns will need to be acoustically boxed to prevent sound test failure.

ACOUSTIC_DESIGN

One such acoustic treatment for steel columns or beams would be to construct a free standing metal or timber stud partition around the column, incorporating 50mm insulation quilt and sheeted with two layers of gypsum-based board. Where columns pass through separating floors, as in old bonded warehouses, the junction between column and floor should be well sealed not only for sound insulation but also for fire. The column linings should be double lined with gypsum-based board (minimum mass per unit area 10kg/m2).

Timber beams do not significantly affect the sound insulation performance of a separating floor. However, if a beam has been installed for strengthening, the boxing around the beam may be a single sheet of lightweight board and the board may be fixed directly to the beam resulting in a noise flanking path for airborne and impact sound. This can be resolved by stripping off the boxing, packing any voids with dense mineral wool batt and re-sheeting with two layers of dense gypsum-based sound board.

We hope the above information helps you to understand the potential problems with acoustic design and pre-completion sound testing on your development. If you have a project that’s requires acoustic design advice or sound testing in London, then please contact us at: info@aptsoundtesting.co.uk  or phone us directly on 07775623464.

The two types of sound insulation testing through floors.

There are two distinct types of sound insulation testing through floors, they are:

  1. Airborne Noise (for example speech and music)
  2. Impact Noise (for example footsteps directly on the floor above)

In the event of  both types of sound – Airborne & Impact) are emitting excessive noise through the ceiling/floor, then there are some easy installations that should reduce the sound levels and improve your sound test results.

sound testing equipment

We also offer an acoustic design service which helps clients to pass the sound testing upon completion of the acoustic upgrade. By advising on a simple cost effective wall and/or floor upgrade, we are able to forward simple to follow acoustic design reviews, utilising our extensive knowledge of different materials and construction methods. Where our acoustic upgrades have been incorporated into the site construction, all the pre-completion sound tests have passed, ensuring compliance with Part E of Building Regulations.

Pre-completion sound testing has been a mandatory requirement since 2003 and all new build properties and conversions which were built after this date require 10% of each party wall/floor construction type to be tested. In is usual to test between living rooms and bedrooms as these are classed as the two main habitable rooms; however, other rooms can be used if this is not possible such as study’s, kitchens and dining rooms.

We also carry out a large amount of sound tests in council/housing association blocks, where the residents are experiencing excess noise between the dividing wall and floor partitions.

We provide full UKAS accredited air and sound testing in London, using the latest Class 1 equipment, so our clients can be sure that all testing is completed to a strict ISO quality controlled standard

If you would like advice on your acoustic design or sound testing in London, please contact us now at info@aptsoundtesting.co.uk or call us on 07775623464.

Failed Sound Testing in London?

Failed Sound Testing in London?

When a building fails the Part E Sound Test in London it may be down to a problem with the acoustic construction, this may be down to issues such as noise flanking etc.

Ongoing problems with airborne and structure borne sound are often associated with direct noise flanking transmission through floors and supporting walls and other associated structures such as the external envelope. One common cause of noise flanking and failed sound testing is often associated with the inclusion of lightweight blocks within the construction of the building envelope and/or blocked cavities. It all cases it is essential to establish if your problem is due to direct transmission, flanking transmission or a combination of both so that the most cost effective remedial treatment can be chosen.

Sound Testing in London

Unwanted noise travelling along flanking paths will make the building structure vibrate which causes the sound to radiate into your room. One simple cost effective solution is to build another wall or ceiling in front of the original, but not connected to it (often called an independent wall or ceiling) so it provides isolation between materials.

One way to reduce the chance of flanking transmission is through careful consideration to the design at the start of the project.  Unfortunately, by simply specifying high performance wall and floor partitions it is no guarantee to adequate sound isolation and successful sound insulation testing. APT Sound Testing offer both preconstruction and post construction design solutions to achieve a successful sound testing in-line with Part E of Building Regulations. We also offer onsite inspection services to ensure that the sound insulation elements are being installed as per manufactures guild-lines. Even if both types of sound are emitting through the ceiling/floor then there are some easy installations that should reduce the sound levels and improve your sound test results. By advising on a simple cost effective wall and/or floor upgrade, we are able to forward simple to follow acoustic design reviews, utilising our extensive knowledge of different materials and construction methods

If you have failed a sound test and need acoustic advice on how to overcome the problem then please contact us at info@aptsoundtesting.co.uk or call me direct on 07775623464.

SOUND INSULATION TESTING in LONDON

Sound Insulation Testing in London

APT Sound Testing have a massive amount of experience when it comes to undertaking  sound insulation testing in London. We have the necessary know how and onsite experience to carry out sound insulation testing on a new build or conversion project throughout London for a most competitive prices.

Our engineers carry out the airborne and impact sound test measurements in compliance with Part E of Building Regulations. We have previously undertaken hundreds of sound tests to new build and conversion projects. we also undertake detailed design reviews to ensure our clients achieve a successful sound test.

NoiseFlankingWall

Our engineers also understand the extra coordination that’s required to test within central London, whether its restricted access and/or parking we have it covered. Many other companies that are based outside London literally double their fees when undertaking sound testing in the capital; as we have an office in London we can afford to charge the same flat fee as we do across the rest of the UK.  Also as we are based in London we can usually arrive on site at the agreed time which often minimises delays to planned noisy works on site. We aim to arrive early and leave early.

We undertake London sound testing on all types of projects from simple flat conversions to large new apartment block developments containing many hundreds of flats. We also undertake sound testing where a lease holder dispute has arisen, which is quite common in London. We can undertake sample sound testing to highlight the existing sound insulation performance of the dividing wall and/or floor partitions to allow for targeted acoustic design to keep cost and delays to a minimum.

If you would like more information on our London Sound Insulation Testing package please contact us now at info@aptsoundtesting.co.uk or call me directly on 07775623464.

Careful Consideration to the Acoustic Design will help you pass your Sound Test

Careful Consideration to the Acoustic Design will help you pass your Sound Test

Careful consideration must be shown to the acoustic design from the start of every conversion project to avoid sound test failures. Most floor designs throughout the 1980s, encompassed the following construction details:

  • Floorboards (18–22mm thick)
  • Gypsum-based board
  • Mineral wool batt (80kg/m3)
  • Sub decking
  • 200-220mm joists
  • 100mm quilt insulation between the joists
  • One/Two layers of gypsum-based board for the ceiling

One the most common constructions used a combination of floorboard, gypsum board and mineral wool batt and was termed a “platform floor”. There is a wide range of batt densities. If the density is too low the floor surface is able to ‘bounce’ and deflect much more easily. If the density is too high then the floor may be too hard and impact sound is able to transmit more easily to the residential dwelling below resulting in sound test failure, so it was very difficult picking the correct materials.

ACOUSTIC_DESIGN

Often, even when resilient battens are used, continuous structural contact along the joist between the floor sub-deck and ceiling provides a strong path for sound transmission. If contact between the ceiling and the joists can be reduced, an increase in airborne and impact performance will be achieved.

One solution is to add another ceiling element to the overall construction. This can provide the extra isolation required to pass the sound testing in London.  This can be achieved by incorporate resilient metal bars which are connected to the underside of the joists and mounted perpendicular (90˚) to the joist direction. If plasterboard has already been tacked to the underside of the joists you can firstly add timber batten and then add the resilient bars, also mounted perpendicular (90˚ to the batten, thereafter 2 x 12.5mm layers of soundboard can be tacked to the underside of the resilient bar. Above the floor a resilient membrane can be used to reduce the chance of impact noise transmitting down to dwelling below.

If you require more information about acoustic design and/or sound testing on your project, please contact us now at info@aptsoundtesting.co.uk or call me direct on 07775623464.

The Different Types of Sound testing in London

This article explains the different types of Sound testing in London

There are two different types of sound testing you need to pass to comply with Building Regulations Part E. This article offers a brief description of both.

Airborne Sound Testing in London

The airborne performance requirements of Part E stipulate that new build properties ned to achieve 45dB and converted properties 43dB. This applies both to party walls and floors between properties. This level is the difference between the source level and the receiver level during London sound tests.

If the source level in one flat is 110dB and the receiver level in the neighbouring flat is 55dB, the level difference (or sound reduction performance) is 55dB. Thereafter the measurement is corrected for several factors such as background noise, room characteristics and frequency weighting, giving the final sound insulation performance value of the tested partition.

sound testing equipment

In this case the higher the number achieved the better the sound insulation performance, whereas Impact testing is the opposite, i.e. the lower the figure the better performance. The measurement is done by using a Norsonic Class 1 Analyser, Amplifier and Speaker (as shown below)

Impact Sound Testing In London

Impact sound testing only applies to party floors and related to the effectiveness of the floor construction in absorbing shock such as footfall noise. The measurement is done by using a Norsonic tapping machine (as shown below). The machine has 5 weights which tapping in regular succession on the tested floor which emulates footfall noise. The noise levels are taken in the receiving room below, which are then measured and averaged for different tapper positions, which then gives the sound reduction rating of the floor. In this case the lower the figure, the better the performance.

Impact Sound Testing

If you have a project that’s needs acoustic design advice or Sound Testing in London, then please contact us at: info@aptsoundtesting.co.uk or phone us directly on 07775623464.

How Many Sound Tests Do I Need On My Project

How Many Sound Tests Do I Need On My Project?

Our clients often ask ‘how many sound tests do I need on my project’. Part E stipulated that one set of sound tests needs to be undertaken for every ten flats or houses, provided the construction system is the same. A set means that the test should include two locations where the party element (wall or floor) is tested. This is equivalent to two individual tests when assessing the performance of a wall this means 2 airborne wall, 2 airborne floor and 2 impact sound tests as a minimum wherever possible. All tests must be undertaken between habitable spaces (e.g. bedrooms, living rooms) and not to or from common spaces such as stairwells and corridors.

Acoustic Design Advice

Approved Document E 2003 also states that a minimum of 10% of all party walls and floors is sound tested for every type of construction or sub-group, this means where there a variations in the construction of the floors and/or walls may occur then further testing may be required. The amount of sound tests required for each type of development is:

Houses:

On houses two airborne sound insulation tests on a pair of separating walls would be required.

Flats:

On flats a 6 Pack would normally be required, this would usually comprise of two airborne sound insulation tests on separating walls; two airborne sound insulation tests of separating floors and two impact sound transmission tests of separating floors

Rooms for Residential Purposes:

On student accommodation, hotel rooms & care homes a set of tests would usually comprise of one airborne sound insulation test of a separating wall; one airborne sound insulation test on a separating floor and one impact sound transmission test of a separating floor.

If you are unsure of the amount of sound tests required on your development, please contact us now at: info@aptsoundtesting.co.uk or call me direct on 07775623464.