IMPROVING SOUND INSULATION ON LONDON REFURBISHMENT PROJECTS

IMPROVING SOUND INSULATION ON  LONDON REFURBISHMENT PROJECTS

Many of our new clients ask ‘ how can we improve our sound insulation on our London Refurbishment projects’. One of the main problems is that a large number of the dwellings in London, consist of flats converted from large Victorian houses. Unfortunately at the time of the building conversion, designing for sound insulation was not a high priority and so many of the dwellings suffer from adverse noise transference between the floor and wall partitions. This can be extremely stressful to the occupant’s well being is a major cause for concern.

There are ways to improve the airborne and impact performance by improving the wall/floor partitions ability to reduce the amount of sound transmission from one side of a construction element to the other. By isolating the different materials may not be enough its own and you may need to improve the mass of the partition as well.

Video Showing Main Noise Transference Points Through Existing Partitions.

Improving Existing Floor Partitions

In our experience of undertaking hundreds of sound insulation tests in London, refurbishment projects usually achieve 30-35dB for airborne sound and 70dB for Impact Sound, if the existing construction has not been acoustically upgraded. These figures do not meet the required 43dB & 64dB as stipulated in Part E of Building Regulations. As sound double every 10dB this is a massive failure and acoustic improvements must be made. Many existing construction consist of a similar construction as shown in as detail 1 below.

Detail 1: Existing Floor Partitions Rated At Approx. 30dB

 Failed_sound_Testing_Due_to_existing_floor_Construction_

Acoustic Improvements to Existing Floor Partitions

To reduce airborne and impact sound transmission this usually means adding density and isolation to the floor construction. This can be as simple as adding a drop ceiling consisting of 125mm timber frame. The top of the frame must be a minimum of 25mm below the existing ceiling finish – such as lathe and plaster. Then, to the inside of the timber frame add 100mm of Acoustic Wool and two layers of sound-board tacked to the bottom of the timber frame – all boards to be lapped. This should improve your sound test results by approx. 10-15dB depending on the existing site conditions and quality of the installation. Detail 2 shows this in more detail.

Detail 2: Acoustic Flooring Partition Upgrade

Simple_floor_upgrade_to_Pass_Sound_Testing

If you would like advice on your acoustic design or require sound insulation testing in London, please contact us now on 07775623464 or contact us at info@aptsoundtesting.co.uk.

Sound Testing In House Conversions

Sound Testing Results in House Conversions.

 Due to the housing shortage many houses are being converted into flats, which has resulted in a massive spike in noise complains amongst neighbours in such developments. Much of this rise in complaints are due to insufficient acoustic design at the start of the project, this means the dividing partitions are not being designed or constructed to comply with Part E of Building Regulations for Conversions.

 In our experience many of the sound insulation tests we undertake on refurbishment projects achieve 30-35dB for airborne sound, which is well below the required 43dB as stipulated in Part E. For impact sound testing, the figures are usually around 70dB which is well above the required 64dB, which is also a massive failure.

 Taking the above into account is it essential that the acoustic design is addressed right from the start of the refurbishment project.  The usual existing construction is 175mm joists with floorboards attached to the top and a single layer of plasterboard – as per the below detail:

Failed_sound_Testing_Due_to_existing_floor_Construction_

Upgrades or changes to the buildings structure, i.e. previous service works for water pipes, drainage and heating systems may have removed acoustic materials or interfered with acoustic isolation. This can lead to a wide disparity in performance between damaged and undamaged floors or walls.

 To overcome many of these issues we can visit site and undertake sample sound insulation testing through your property to establish the current noise levels. Once the noise levels have been established we can advise on acoustic upgrades to help you improve the sound insulation levels. it may be as simple as the installation of an acoustic resilient layer on the floor, or a minor wall upgrade.

APT SOUND TESTING

APT are an Independent UKAS Accredited Testing Company

We specialise in all types of sound insulation testing for Approved Document E of the Building Regulations including BB93  sound testing for schools. We carry out Airborne & Impact Tests in accordance with ISO140 Parts 4 & 7 and Building Facade Testing in accordance with ISO140 part 5.

We have a considerable amount of experience in how buildings are constructed and specialise in acoustic design advice in both the design stage (before construction begins) and also remedial works in the event of a partition failing the tests. We have worked on numerous projects where a customer has failed the sound tests and then been able to achieve a pass following the installation of a retrofit product that has been chosen based on the specific requirements of the project.

If you would like more information on the above, please contact us on 01525 303905.