The Difference Between Laboratory and Site Sound Testing

The Difference Between Laboratory and Site Sound Testing

Many suppliers of acoustic insulation products quote laboratory sound test results  to demonstrate the performance of their systems. This often causes considerable confusion regarding how well products will perform as there are usually large differences between the laboratory and site conditions. For instance laboratory sound tests do not take account of flanking sound and therefore produce sound insulation figures that would be very difficult to achieve on site.

sound testing

Despite site contractor’s best endeavours, it is extremely difficult to build to the stringent exacting standards of the test laboratory. When the construction assembly is undertaken in the lab, it has gone through an exacting installation technique prior to the sound test, which is also a contributing factor why better sound testing levels are achieved.

Throughout the acoustic installation the manufacturer’s guidance is followed to the letter by the lab technicians. Although, this should be replicated on site, it seldom is due to time constraints etc. and so a design which can be easily in excess of the requirements of approved document E, can often lose approx. 8-10dB compared to the laboratory results. Unfortunately there may be many reasons for poor sound test results such as poor quality site installation as well as other on-site issues where cost, time and programming constraints may come into play.

architect drafting a house blueprint

architect drafting a house blueprint

One important thing to consider is that most building structures will be subject to varying amount of flanking sound, so field sound test data should show the real performance of a system in a building. Laboratory sound insulation tests simply measure sound and do not account for flanking sound transmission.

If you are worried about your projects acoustic design and/or have questions about the precompletion sound testing, please don’t hesitate to contact us now at: info@aptsoundtesting.co.uk or Darren direct on 07775623464. 

How to Improve your Sound Test Results

How to improve your Sound Test Results

If you have started a new or conversion development, it is important that from the offset you realise that you will need to comply with stringent sound insulation requirements of Approved Document E. Both new and converted residential dwellings use must meet the standards stipulated in Approved Document E. Part E states that the separating floor partition (floor between two separate dwellings) must achieve sound insulation figures of 45dB for airborne sound and 62dB for impact sound on all new builds and 43dB for airborne sound and 64dB for impact sound on converted dwellings; if you don’t achieve the aforementioned results then you will pass the sound testing. 

Building Control will expect you to demonstrate compliance with Approved Document E 2003 by undertaking an independent sound insulation test to prove that you have met the standards for sound insulation between dwellings.

Sound_Insulation_Testing_Equipment

The sound testing must only be carried out by either UKAS or ANC approved companies. If the sound tests are not carried out by approved compaines then Building Control may not accept the sound test report and subsequently it may need to be undertaken again by an approved company costing more time and money.

We are UKAS accredited to undertake sound insulation testing as well as air tightness testing. We offer design advice to help our client achieve Part E sign off. In some cases clients instruct us to proceed with the sound testing, without having carried our any acoustic upgrades or remedial works often resulting in their partitions failing the sound test.

Sound_Testing_Semi_Detached_House

If you are worried about passing your sound testing in London at the first attempt please don’t hesitate to contact us now at: info@aptsoundtesting.co.uk or visit our website at: www.aptsoundtesting.co.uk or call Darren Direct on 07775623464.

Reducing the Chance of Sound Testing failures

Reducing the Chance of Sound Testing failures

The simplest way to reduce the chance of sound testing failures is through careful consideration to the acoustic design at the start of the project.  Unfortunately, by simply specifying high performance wall and floor partitions, it is no guarantee to adequate sound isolation and successful sound testing at the end of the project.

We offer preconstruction design advice to help you achieve successful sound testing in-line with Building Regulations Part E. We also offer onsite inspection services to ensure that the sound insulation elements are being installed as per manufactures guild-lines, as it’s no use having good acoustic design if it not being installed properly on site.

architect drafting a house blueprint

Acoustic Design of Wall and Floor Partitions

The first stage of the acoustic design is to send through the design drawings – to include sections etc. We then review the design to check that the construction details proposed are capable of passing the sound tests. This usually takes place straight after planning has been approved as increased cost savings can be realised at the earliest stage, we will evaluate the construction methods and materials specified to ensure that they are capable of meeting the acoustic requirements of Approved document E. The typical areas we check are:

  1. There are no flanking points, where isolated partitions are wrongly mechanically fixed together to caused noise bridging.
  2. The walls and floors design are acoustically robust, to comply withBuilding Regulations Part E.
  3. The acoustic treatments for Soil Pipes, Stair Cases Steel Beams etc. to ensure they are acoustically fit for purpose, as these are some of the areas that get usually missed.
  4. Acoustic floor treatments are compatible with the proposed floor finishes i.e. Carpets, Laminates, Floor Tiles and under floor heating systems.

APT Sound Testing also provide on-going design support service, so you will have direct contact with the allocated acoustician from the start of the process through to the successful completion of the project. One of the most important services is the going site survey visits which allow our clients to feel confident about the outcome of testing at the end of the build. The site visits let us check that the installation teams are installing the acoustic materials as per manufacturers avoiding crucial onsite mistakes. You can often have a compliant design which still fails due to poor workmanship; the site survey visits negate the risk of sound test failure.

We also offer an acoustic advice service for clients that have failed their precompletion sound testing. We offer simple solutions to reduce the noise levels and achieve compliance with Part E. We can supply simple easy to follow acoustic design reviews, utilising our extensive knowledge of different materials and construction methods

If you require more information about acoustic design and/or sound testing on your project, please contact us now at info@aptsoundtesting.co.uk or call Darren direct on 07775623464.

Why Have I Failed my Sound Insulation Test?

Why Have I Failed my Sound Insulation Test?

This is one of the most common questions clients ask when their property has just failed the sound testing. One of the main reasons for acoustic partitions failing the Part E sound test is often down to poor isolation of material/s, which can lead to excessive noise flanking. Noise Flanking is a term used by acoustic engineers to describe where sound passes through an acoustic partition due to the abutment of materials. The noise simply hits the one side of the wall and then travels through the construction via a noise bridge. This can be areas such as the incorrect use of masonry wall ties i.e. solid fishtail ties, used in place of specified acoustic wall ties; if your building suffers from noise flanking it may result in a sound test failure.

Sound_Insulation_Testing_Equipment

Unwanted noise travelling along flanking paths can make the building structure vibrate, which can cause sound to radiate into your room – as shown in the plate below . One simple cost effective solution is to build another wall or ceiling in front of the original, to offer extra isolation. For this upgrade to work you need to make sure that the independent wall or ceiling is not directly connected to the existing failed partition; so it provides isolation between materials.

Coupled_wall_construction

Noise flanking can also be down to the use of down to the use of lightweight blocks in the construction of the building envelope. Due to the lightweight mas of the inner wall it allows sound to transmit from dwelling to another, both vertically and horizontally. If a building has failed its sound testing, it is essential to establish if the problem is due to direct transmission, flanking transmission or a combination of both so that the most cost and time effective remedial treatment can be designed and applied to the failed partitions.

If you require more information about acoustic design and/or sound testing on your project, please contact us now at info@aptsoundtesting.co.uk or call me direct on 07775623464.

Sound Intrusion Though Windows

Sound Intrusion Though Windows

Sound intrusion though windows can also be a source of great annoyance if the sound is excessive, and in some cases developments have failed the sound insulation testing due to poorly specified and installed windows. Sound intrusion may be down to a variety of factors. If the windows are operable types, the first thing to check is to see if the widows close properly against their seals and any weather stripping is continuous and in good order. If the window leaks air, then more often than not it will usually leak sound. If the window closes to form a tight seal and the weather-stripping seems adequate the next thing to check is the window frame. Windows are frequently installed in to the wall opening with plastic shims to insure the unit is plumb and level. In high traffic areas you will normally require a double glazed unit as a minimum and in some cases a triple glazed unit will be required.

Sound_Intrusion_Through_Windows

The space between the frame and the wall should be insulated and sealed before the window casings are installed. If this was not done correctly you can probably detect the sound leakage by placing your ear close to the frame and listening. The sound may be able to run along the cavity and back into the adjacent property, It is case of letting your ears do the walking and listening. If you detect distinguishable differences in sound you may have found the problem; the solution will be to remove the casing and insulate and caulk all leaks. In some cases the thickness of the glass maybe the problem in which case it may be necessary to install another layer of glass on the inside of the existing frame making sure that the additional pane of glass is well sealed into the opening.

In some instances you may be able to lower excessive sound by installing a heavy curtain – especially if the house is in a conservation area and as a result the local authority will not let you change or upgrade the windows.

If you require more advice on your project and/or you require precompletion sound testing, please contact us at: info@aptsoundtesting.co.uk  or phone me directly on 07775623464.

Remedial action following a sound insulation test failure

Remedial action following a sound insulation test failure

If a partition fails a sound insulation test, it can be difficult to provide definitive guidance on resolving specific problems that have occurred in individual buildings as the building is usually complete at the time of testing. However, using our knowledge of acoustic construction and detailing APT Sound Testing are usually able to identify and resolve any problems with the acoustic partitions.

ACOUSTIC_DESIGN

If the sound testing failure is attributed to the construction of the separating and/or associated flanking elements, other rooms that have not been tested as part of the testing schedule may also fail to meet the test performance levels. Additional tests may be needed, over and above the number recommended under Building Regulations Part E.

Extra sound testing will assist in identifying, at an early stage, where the failures have been caused by intermittent poor workmanship and/or design. Sound Testing may then be required for all plots to identify the ones that require remedial treatment. Where failure is due to a design fault, additional testing may not be required, as all plots with the same design are likely to require remedial treatment and so a generic acoustic upgrade can be undertaken to the failed partitions and then retested thereafter.

sound testing

To try and negate potential problems with the sound insulation testing we offer the following 4 step acoustic design advice package:

  1. Site Survey Visits – to let us view the existing site construction. This allows us to check for potential problematic construction detailing and also lets us check that the installation teams are installing the acoustic materials as per manufacturer’s guidelines.
  2. Sample Sound Testing – of the existing construction. This offers an accurate overview of the acoustic performance of the existing partitions.
  3. Design Review – a full design review of the proposed developments party walls and floors.
  4. Pre-completion Sound Testing to satisfy Approved Document E.

APT Sound Testing can supply a ‘one stop’ solution for all your acoustic requirements. If you would like more information in regards to sound insulation testing or acoustic design please contact us at: info@aptsoundtesting.co.uk  or call Darren direct on 07775623464.

Sound Test Report Information

Sound Test Report Information

All our testing and reportage are undertaken in strict accordance with Annexe B of Approved Document E of the Building Regulations and BS EN ISO 140-4:1998 “Field measurements of airborne sound insulation between rooms” and BS EN ISO 140-7:1998 “Field measurements of impact sound insulation of floors.”

Acoustic_Design_Service

After the sound insulation test a sound test report or certificate should be provided in compliance with Building Regulations Part E. This normally provides the following information:

  1. The company name and/or testers name and address that carried out the test and the accreditation held by the membership organisation.
  2. The client/applicant name.
  3. Site address.
  4. Plots tested
  5. If it was a wall or floor test.
  6. List of equipment used (including details on calibrated equipment) and testing technique.
  7. Confirmation that the test was in accordance with BS EN ISO 140 Part 4 (airborne) and Part 7 (impact).
  8. Measurement procedure.
  9. The results should be calculated in accordance with BS EN ISO 717-1 and 717-2 1997. Detailed test results giving a declaration of a pass or fail.
  10. Date of test. The test results or certificates will be submitted to the verifier during the completion certificate process.

The test duration depends on the amount of sound insulation tests required on the project. Taking into account standard site conditions a set of two airborne wall tests (for a pair of houses) will take one to two hours. A six pack of tests on flats, consisting of two airborne walls, two airborne floor and two impact tests will take between two to three hours. Throughout the sound testing we will require full free uninterrupted access to the units/rooms in all test areas.

We offer an acoustic design service to review the construction detailing. We also offer a sample testing service along with site inspections which provides a ‘one stop acoustic solution’. We visit site during the build process to check for any workmanship issues that may cause problems during the final pre-completion sound testing.

If you would like APT Sound Testing to review your sites acoustic construction, then please speak to us about our acoustic design service, alternatively if you just require sound insulation testing please contact us at: info@aptsoundtesting.co.uk

Acoustic Design Advice

Acoustic Design Advice

To try and help our clients achieve compliance with Approved Document E, we offer the following 4 step acoustic design advice package:

  1. Site Survey Visits – to let us view the existing site construction. This allows us to check for potential problematic construction such as inclusion of lightweight blocks in the existing construction. It also lets us check that the installation teams are installing the acoustic materials as per manufacturer’s guidelines.
  2. Sample Sound Testing – of the existing construction. This offers an accurate overview of the acoustic performance of the existing partitions which enables us to offer a targeted acoustic design using the sound insulation performance of the existing construction.
  3. Acoustic Design Review – a full design review of the proposed developments party walls and floors.
  4. Pre-completion Sound Testing to satisfy Approved Document.

ACOUSTIC_DESIGN

There are many factors to consider when considering good acoustic design, and they are usually split up into five key factors. If used together or in various combinations they will improve sound insulation properties over a wide range of frequencies. The main factors are:

  1. Mass
  2. Isolation
  3. Absorption
  4. Resilience
  5. Stiffness

Also, noise flanking transmission may in some cases be the dominant pathway between adjoining dwellings, especially in existing buildings where you are planning to convert offices/large houses into flats. Here are just a few of the potential noise flanking areas:

  1. Structural Steels
  2. Windows built very close to Internal partitions
  3. Inner leaf of the external wall
  4. External wall cavities
  5. External façade or outer leaf
  6. Roof structure

APT Sound Testing can advise on all types of acoustic design, whether it’s accomplished during initial construction or during a refurbishment/renovation project. We also undertake UKAS accredited sound insulation testing providing a ‘one stop’ solution for all your acoustic requirements.

If you would like more information in regards to sound testing please contact us at: info@aptsoundtesting.co.uk or 07775623464 or visit our website at: www.aptsoundtesting.co.uk

Sound Insulation Testing

Sound Insulation Testing

At APT we offer Airborne and Impact Sound Insulation Testing in accordance with Part E of the Building Regulations and, where required sound testing on Schools BB93 & BREEAM. Under Part E of Building Regulations, this is a requirement for new and converted dwellings where there is a separating partition wall or floor. The sound insulation testing of existing buildings is carried out to assess current levels of sound insulation and to allow for the design of remedial measures, where the performance needs to be increased.

The buildings that currently require sound testing are:

  1. Dwelling-houses, flats or rooms for residential purposes created by conversion of existing buildings or new build rooms for residential purposes will need to be tested if work starts after 1 July 2004.
  2. New build dwelling-houses and flats will need to be tested if work starts after 1 July 2004.

Sound insulation testing is carried out to ensure that minimum standards of sound resistance have been met to ensure the well-being of new tenants is not compromised by adverse sound transmission. The testing checks that the dividing partitions have not been compromised by poor workmanship and poor design. We use the latest sound testing equipment as shown below:

sound testing equipment

You are normally required to undertake sound testing to each type of construction, i.e. if you have a mixture of brick, block-work, timber and metal stud-work walls all four types would need to be tested, followed by a 10% sample of that type. it is worth noting that if any test failures occur, then the number of sound tests may need to increase on the development.

If you are unsure whether the Regulations apply to your development or if your site needs sound insulation testing, please call your local office or email us at info@aptsoundtesting.co.uk where our team will be happy to discuss all aspects of acoustics or sound insulation within buildings, and explain the testing procedure.

Simple Acoustic Upgrades

Simple Acoustic Upgrades

There are many simple acoustic upgrades you can undertake to improve the sound insulation values of your dwelling. Plate A below shows one cost effective ceiling upgrade that can be undertaken on conversion projects. Firstly retain the existing floor joists – check them for general wear and tare) then above the joists install 22mm chipboard. Above the floor board install an acoustic resilient membrane and above this install the 22mm engineered floor. Within the joist cavity install 100mm AW IsoWool. To the underside of the joists fix a resilient hanger system and below this install two layers of 12.5mm sound boards ensuring that boards have adequate laps. It is worth noting that although the above system should work, it is essential that you contact us before going ahead with any works as each project is different and may require extra acoustic design input.

Plate A – Acoustic Floor Upgrade

Good Conversion Diagram - 15-01-16Also, to try and help our clients achieve compliance with Approved Document E at the first attempt we offer the following 4 step acoustic design package:

  1. Site Survey Visits – to let us view the existing site construction. This allows us to check for potential problematic construction such as inclusion of lightweight blocks in the existing construction. It also lets us check that the installation teams are installing the acoustic materials as per manufacturer’s guidelines.
  2. Sample Sound Testing – of the existing construction. This offers an accurate overview of the acoustic performance of the existing partitions which enables us to offer a targeted acoustic design using the sound insulation performance of the existing construction.
  3. Acoustic Design Review – a full design review of the proposed developments party walls and floors.
  4. Pre-completion Sound Testing to satisfy Approved Document E.

APT Sound Testing can advise on all types of acoustic design, whether it’s accomplished during initial construction or during a refurbishment/renovation project. We also undertake UKAS accredited sound insulation testing providing a ‘one stop’ solution for all your acoustic requirements.

If you would like more information in regards to sound testing please follow our blog at: http://soundtestinguk.blogspot.co.uk or contact us at: info@aptsoundtesting.co.uk and 07775623464 or visit our website at: www.aptsoundtesting.co.uk