Acoustic Terminology A-B

Acoustic Terminology A-B

Often confusion can arise from the large amount of ‘terms’ used in conjunction with acoustic design and sound insulation testing. To help with this we have made a list of the following terms along with a quick explanation:

 Absorption

This is the conversion of sound energy into heat, often by the use of a porous material.

Absorbent Material

This is a material that absorbs sound energy, such as acoustic mineral wool.

Airborne sound

This is sound which is propagated from a noise source through the medium of air. Examples of these are speech and sound from a television

Airborne Sound Transmission

This is direct transmission of airborne sound through walls or floors. When sound energy is created in a room, for instance by conversation, some of the energy is reflected or absorbed by room surfaces but some may set up vibrations in the walls and floor. Depending on both the amount of energy and the type of construction, this can result in sound being transmitted to adjacent parts of the building.

Air Path

This is a void in construction elements, which adversely affects the performance of sound resisting construction. Examples of air paths include incomplete mortar joints, porous building materials, gaps around pipes and shrinkage cracks – this can also effect the air tightness results.

 Bonded resilient cover

This is a thin resilient floor covering normally of minimum 3-5mm thickness, which is bonded to the isolated screed surface to reduce impact sound transmission such as footfall noise, however it has a lesser effect when it comes to airborne noise.

Acoustic_Site_Survey

If you have a project that requires acoustic design and/or sound testing please let us know. APT Sound Testing will ensure you will have direct contact with the allocated acoustician from the start of the process, through to the successful completion of the sound insulation testing.

If you would like more information in regards to acoustic services, please contact us at info@aptsoundtesting.co.uk or visit our website at: www.aptsoundtesting.co.uk

Our Acoustic Services

Our Acoustic Services

APT Sound Testing offers a full turnkey solution for all your acoustic requirements to ensure compliance with Building Regulations Part E and achieve building control sign off for the acoustic elements of the project. This ensures your company receives professional advice every step of the way, with an on-going continual consideration of cost.

Our acoustic services consist of the following elements:

Sample Sound Insulation Testing

We visit site to undertake sample sound testing to the existing buildings walls and floors to check the sound insulation performance of the existing dividing partitions. Thereafter, once the sound levels have been established and targeted acoustic design can be undertaken to ensure compliance with Building Regulations Part E.

sound testing equipment

Acoustic Design Service

We can help develop the acoustic design of the project from the initial design scheme stage through to the precompletion sound testing. In particular we review the acoustic details to take into account the mass, isolation and absorption elements of the construction.

Site Survey Visits

We offer site survey visits which allow you (the client) and your contractor to feel confident about the outcome of testing at the end of the build. The site visits let us check that the installation teams are installing the acoustic materials as per manufacturers avoiding crucial onsite mistakes. You can often have a compliant design which still fails due to poor workmanship; the site survey visits negate the risk of sound test failure.

Acoustic_Site_Survey

Sound Test Failures

If your building fails the sound testing, we can use our experience in building construction and acoustics to firstly diagnose the reasons for the sound test failure and thereafter recommend a cost-effective solution to allow you to achieve building regulation compliance.

If you have a project that’s needs acoustic design advice or sound testing in London, then please contact us at: info@aptsoundtesting.co.uk or phone us directly on 07775623464.

Good Acoustic Design Considerations

Good Acoustic Design Considerations

In our experience careful consideration to acoustic design should be undertaken from the start of the project, if this process is followed it usually results in successful precompletion sound testing in compliance with Building Regulations Part E.

In many cases sound test failure can be down to the poor workmanship rather than acoustic design, that is why we offer a full acoustic package which includes for site survey visits; that way we you can be safe in the knowledge that you have the acoustic design and onsite construction covered, reducing the chance of sound test failure.

sound testing equipment

Here are some simple acoustic design tips:

  • Ensure all penetrations are fully sealed where they terminate through floors and they are adequately boxed with acoustic quilt and two layers of plasterboard.
  • Use resilient acoustic hangers within the ceiling design to provide isolation between materials.
  • Avoid the use of lightweight blocks in the inner envelope construction as sound will travel both vertically and horizontally from dwelling to dwelling.
  • Ensure all support steels/timbers are carefully boxed out where they travel from flat to flat vertically and horizontally.
  • Use a high quality resilient acoustic membrane on top of the floor to improve the impact performance of a floor.

In our experience by simply designing and constructing a good separating wall or floor it may not provide sufficient sound insulation to comply with Building Regulations Part E as the junctions of each separating wall and/or floor with other parts of the building are as equally important. One of the main problems with partition failure is down to noise flanking, this can occur via construction components such as:

  • The internal partitions
  • The inner leaf of the external wall
  • The external wall cavities
  • The external façade or outer leaf
  • The roof structure
  • The foundations.

Flanking sound transmission may in some cases be the dominant pathway between adjoining dwellings, especially in existing buildings where you are planning to convert offices/large houses into flats and lightweight materials have been used in the wall construction. If the acoustic consultant has not been made aware of the existing construction it may increase the chance of sound testing failures.

If you have a project that’s needs acoustic design advice or sound testing in London, then please contact us at: info@aptsoundtesting.co.uk or phone us directly on 07775623464.

Acoustic Design Service

Acoustic Design Service

The importance of good acoustic design and construction should not be under estimated. If a project fails its precompletion sound testing it may need costly remedial works to comply with Building Regulations Part E.

On new build developments we offer comprehensive acoustic design via coordination with the lead consultant. We can also visit site during the construction process to undertake a detailed site survey visit to check the onsite construction is as per the construction details – this is often good to ensure the relevant parties are fully aware of the installation detail required, which in turn may highlight possible ‘onsite’ construction problems.

Acoustic Design Service in London 

Acoustic_Site_Survey

On conversion projects we can visit site and undertake sample sound testing, this will evaluate the performance of the existing floor and wall partitions, which allows for targeted acoustic design as the acoustic performance of the dividing partitions may be already good –  especially if the buildings floors are constructed out of cast in situ concrete.

APT Sound Testing  provides a consultancy design service to Architects, Property Developers and Building Contractors. We specialise in helping small developers pass their sound testing to achieve Part E compliance for all types of project such as new build properties, blocks of flats and conversions.

Sound_Testing_Flats

Many of our clients have previously conveyed negative feedback that larger acoustic consultancies don’t understand small builder requirements and subsequently often produce complicated acoustic design detailing that are both difficult (in terms of build-ability) and very costly to undertake. We try to provide acoustic solutions that are cost effective and easy to construct, saving our clients time and money.

If you would like more information in regards to our acoustic design service and/or sound testing please follow our blog at: http://soundtestinguk.blogspot.co.uk/, or contact us at: info@aptsoundtesting.co.uk or visit our website at: www.aptsoundtesting.co.uk

 

Sound Testing for Leasehold Agreements

Sound Testing for Leasehold Agreements

One of the main reasons for neighbour disputes is down to the fact that floor modifications may have taken place without the flat owner, first consulting his/her leasehold agreement. In many cases the lease agreement contains something similar to the following conditions:

Sound Testing through Floors

Part-E-Sound-Testing

‘If the tenant wants to change the floor construction within his dwelling he shall’:

  • Commission an independent acoustic consultant to carry out a pre installation test, design the new acoustic installation and carry out a post installation test and provide the results to the landlord’s surveyors for approval; and
  • Invite the Landlord’s surveyor to inspect the acoustic insulation before it is concealed; and
  • Accept that the Landlord, whilst granting this Licence, does not accept any responsibility for the design or performance of the insulation provided and that if any issues arise the Tenant will address these immediately. In the event of reasonable complaint being upheld by the Landlord or his agent concerning noise affecting other Tenants within The Building, the Tenant will arrange for carpeting (the provision of which shall be determined by the Landlord) to be positioned and maintained at the Tenant’s sole cost;

We offer a comprehensive acoustic service to let our clients comply with their leasehold agreements.

  • Pre-works Sound Testing of the existing construction. This offers an accurate overview of the acoustic performance of the existing floor partition/s prior to the commencement of construction works. It also enables us to offer a targeted acoustic design using the sound insulation performance of the existing construction.
  • Acoustic design review – once we have the performance figures from the sample sound testing have been established, we can forward a design that should improve the performance of the existing floor partition – even if you are changing the floor from a carpet to engineered timber floor finish!
  • Site Survey Visit – This allows us to check that the installation team is installing the acoustic materials as per manufacturer’s guidelines.
  • Final Precompletion Sound Testing in-line with Approved Document E. This provides an accurate overview of the acoustic performance of the upgraded partition/s, the results of which can be handed over to the relevant person for sign off.

If you are about to make changes to your apartment floor, and you require acoustic design advice, then please contact us now at: info@aptsoundtesting.co.uk  or phone me directly on 07775623464.

 

Noise Complaints in Existing Apartment Blocks

Noise Complaints in Existing Apartment Blocks

Over the last few years we are noticing a rise in noise complaints in existing apartment blocks. There may be many reasons for this. Noise problems range from airborne noise transmission from voices TVs and music to footfall impact noise caused by high heels on wooden/tiled floors – it is usually the impact noise that is noticed most by the residents if the unit above has changed their floor finish from carpet to wood.

Excessive-Noise

In many cases even if the floor assembly has been designed and constructed to provide adequate airborne isolation, impact noise can still be a major problem. One of the main problems is if works to the floor finish have been undertaken, changing it from carpet to timber. Even if it passes the sound test, the perceivable rise in impact noise often leads to complaints, as carpet and underlay normally provides a good degree of impact sound isolation. Taking this into account it’s very important that impact isolation design, is taken into account before the installation of a hardwood and/or ceramic tile finish.

If you think you may have a problem with sound in your dwelling and/or you have encountered complaints from a neighbour due to changes you have made to the floor finish then please contact us now. Try to describe the noise problem in as much detail as possible. Describe the nature of the sounds, when and where you or your neighbour can hear it. Is it impact noise or airborne noise or a combination of both? The more information you can provide us, the quicker we can try to determine the nature of the problem and find a solution. It may be as simple as the installation of an acoustic resilient membrane to the floor.

Acoustic_Site_Survey

In our experience, if careful consideration is shown to the acoustic element of the floor upgrade, it should reduce the chance of complaints at a later stage, which will also avert costly legal battles at the end of the project and which often leads on to expensive remedial works.

We can come in prior to works commence and undertake a sample sound test of the existing floor partition, thereafter we can advise on the acoustic design of the floor. once the works have been completed we can then undertake a final precompletion sound test to show compliance with Building Regulations Part E.

If you are about to make changes to your apartment floor, and you require acoustic design advice, then please contact us now at: info@aptsoundtesting.co.uk  or phone me directly on 07775623464.

The Different Types of Sound Insulation Testing

The Different Types of Sound Insulation Testing

Sound Testing has been mandatory requirement since July 2003. All new build dwellings and conversions which were built after this date require 10% of each party wall/floor construction type to be tested.

Sound Insulation Tests needs to be carried out between pairs of rooms separated by party walls or floors, i.e. in block of flats you would undertake airborne testing across the walls and floors; and impact tests across the floors.

Sound_Testing_Flats

You usually try to undertake testing between the two main habitable rooms, such as living rooms and bedrooms. The sound test procedure involves setting up a noise source in a room on one side of the party wall or floor and measuring the noise on both sides of the partition with a class 1 analyser.

Airborne Sound Insulation Tests

Airborne sound insulation tests may be required between horizontally and vertically separated pairs of rooms. The sound tests are undertaken by using a sound source, amplifier and loudspeaker to generate a high noise level in one room (the source room). Noise measurements are then taken in both the source and receiver rooms using a prescribed number of source and microphone positions.

Sample_Sound__Testing

The background levels in the receiver room are measured and the reverberation time in the receiver room is also measured. From the results, the airborne sound insulation (DnT,w + Ctr) is calculated and compared to the requirements of Approved Document E.

Impact Sound Insulation Tests

For vertically separated rooms Impact sound Insulation testing may also be required. This sound test is undertaken using a “tapping machine”, (as above) which drops a series of weights onto the floor of the upper room. The noise level in the lower (receiver) room is measured for a prescribed number of source and microphone locations. The background levels in the receiver room are measured and the reverberation time in the receiver room is also measured. From the results, the impact sound insulation (L’nT,w) is calculated and compared to the requirements of Approved Document E.

Impact Sound Testing

We use the latest Norsonic equipment, which is class one rating and UKAS calibrated. We are a UKAS and ISO accredited company, so you can be assured all our testing is carried out to the strictest quality controlled standards.

If you would like more information in regards to sound testing please follow our blog at: http://soundtestinguk.blogspot.co.uk/, or contact me (Darren) on 07775 623464 ot email us at info@aptsoundtesting.co.uk

Sample Sound Testing

SAMPLE SOUND TESTING 

Sample sound testing is the cornerstone of acoustic design when it comes to the conversion of commercial buildings into residential developments. We can undertake sample sound testing to the existing buildings walls and floors to check the sound insulation performance of the existing dividing partitions. Thereafter, once the sound levels have been established and targeted acoustic design can be undertaken to ensure compliance with Building Regulations Part E.

Sound_Testing_Flats

We offer a proactive approach to acoustic design, onsite construction checks and sound testing. This ensures your company receives professional advice every step of the way, with an on-going continual consideration of cost. Our main acoustic services consist of the following.

Sample Sound Insulation Testing

We undertake sample sound testing to identify the sound levels for the existing partitions. Thereafter a more targeted acoustic design can be undertaken to the partitions saving time and money through the construction process.

Sample_Sound__Testing

Acoustic Consultancy  

We have considerable experience in all matters related to architectural acoustic design and detailing. We can help develop the initial acoustic design of the project from the initial design scheme stage, in particular acoustic isolation, and interior acoustics. We also use the latest Norsonic equipment analysers and sound sources for conventional and binaural acoustic measurements.

Site Visits

We offer site visits which allow you (the client) and your contractor to feel confident about the outcome of testing at the end of the build. The site visits let us check that the installation teams are installing the acoustic materials as per manufacturers avoiding crucial onsite mistakes. You can often have a compliant design which still fails due to poor workmanship; the site survey visits negate the risk of sound test failure.

Acoustic_Site_Survey

Precompletion Sound Insulation Testing

We undertake the final precompletion testing to ensure compliance with Building Regulations Part E and achieve building control sign off for the acoustic elements of the project.

If you would like more information in regards to sound testing or acoustic design, please follow our blog at: http://soundtestinguk.blogspot.co.uk/, or contact us at: info@aptsoundtesting.co.uk or Darren on 07775623464, or visit our website at: www.aptsoundtesting.co.uk

Excessive Noise Flanking can lead to Sound Test Failure

Excessive Noise Flanking can lead to Sound Test Failure

Noise Flanking is a term used by acoustic engineers to describe where passes sound over the top or under the primary partition separating the two spaces under test. Noise flanking usually appears due to insufficient isolation of materials thus allowing sound to travel through the partition. Unfortunately excessive noise flanking can lead to a sound test failure.

Noise_flanking

One way to reduce the chance of noise flanking transmission is through a careful consideration to the acoustic design from the start of the project.  Unfortunately, by simply specifying high performance wall and floor partitions it is no guarantee to adequate sound isolation and successful sound testing, extra care must be shown to the mass, isolation and absorption values of the acoustic construction.

APT Sound Testing offer both preconstruction and post construction ‘remedial’ design solutions to achieve a successful sound insulation testing in-line with Part E of Building Regulations. We also offer onsite inspection services to ensure that the sound insulation elements are being installed as per manufactures guild-lines.

Acoustic_Design_Service

Also, in our experience it is never safe to assume because the architect has specified high performance walls, windows and floor/ceiling assemblies that the materials and onsite workmanship will result in compliance with the anticipated results. You should usually reduce the acoustic target by at least 4-5dB due to onsite construction. When the construction assembly is tested in the lab, it is also certified and the installation techniques are described in detail and the construction is undertaken within Laboratory conditions, which is a far more controlled and scrutinised environment. Unfortunately, it is not always possible to replicate Laboratory conditions on site due to its more chaotic nature with multiple trades working next to each other. This is the reason why a 5 point difference is allowed between the construction design on paper and the actual on site sound testing performance.

We have undertaken hundreds of acoustic design reviews on all types of projects to help our client achieve compliance with Building regulations Part E, we provide a ‘one stop’ solution for all your acoustic requirements.

If you would like more information in regards to our acoustic design service and/or sound testing service, please follow our blog at: http://soundtestinguk.blogspot.co.uk or contact us at: info@aptsoundtesting.co.uk or call me ‘Darren’ direct on 07775623464.

 

How Is Sound Insulation Testing Carried Out

How Is Sound Insulation Testing Carried Out?

For airborne wall and floor sound tests, two individual speaker positions are used for each source room; with a total of ten individual 1/3 octave band measurements recorded for both the source and receiver rooms. Measurements are then made to monitor the levels in the receiving room of the tested partition in question. This gives a basic level difference between source and receiver rooms.

Sound_Insulation_Testing_Equipment

This basic level difference is then ‘corrected’ to allow for the reverberation time (the time taken, in seconds, for a noise source to decay by 60 dB) and the existing levels of background noise monitored whilst in the receiving room.

All our tests are carried out in full accordance with BS EN ISO 140-1998 parts 4 (airborne sound testing) and 7 (impact sound testing), and the calculation of all single figure results are done so in accordance with BS EN ISO 717:1.

How do I know when my site is ready for Sound testing?

Sound testing is typically conducted when a development nears completion, and once all internal and external doors and windows have been fitted, it is worth noting that no carpets should be installed prior to the sound testing.

To be able to conduct sound insulation testing we a constant supply of 240V power; we cannot use generator power. We also require a quiet site (a noisy site can make conducting the tests extremely difficult), so no drilling, jack hammers etc. should be used whilst the testing is taking place. We also require full access to all rooms to either side of the dividing partition so if it is a requirement to access a neighbour’s property, this must be arranged prior to the test date.

Noise_during_sound_testing

If you require a sound insulation test than contact us know, we will explain what the test entails and send you our informative checklist to help you prepare for the test. It is our mission to ensure our clients pass their testing at the first attempt. We pride ourselves on providing a ‘one stop acoustic solution’ for all your acoustic requirements.

If you would like more information in regards to our acoustic services, including acoustic design reviews, sound testing and noise surveys please contact us at: info@aptsoundtesting.co.uk or call Darren on 07775623464 or visit our website at: www.aptsoundtesting.co.uk