The Two Types of Sound Insulation Test

The Two Types of Sound Insulation Test

There are two types of sound insulation testing, Airborne and Impact.

Airborne sound testing is undertaken to walls & floors. Firstly a controlled noise is generated by an amplifier and loudspeaker across a broad range of frequencies. The generated noise is very loud and is often in excess of 100dB. Initial measurements are taken using a class 1 sound level meter within the ‘source room’ followed by further measurements in the ‘receiver room’ on the other side of the wall or floor under investigation. The source room speaker position is then changed and the measurements repeated either side of the partition under test.

Sound_Insulation_Testing_Equipment

Thereafter background noise measurements are made using a class 1 sound level meter in the receiving room and are used to apply appropriate corrections for external sound such as traffic noise. Similarly the reverberation time (the time taken for sound to decay by 60dB) is measured within the receiving room using the sound source and a sound level meter to determine the corrections that must be applied to account for the absorptive characteristics of the room.

The difference in the two airborne noise levels (for walls and floors), corrected for background and reverberation characteristics determines the airborne sound insulation performance of the wall, or floor. A greater airborne noise difference between the source room and the receiver room determines a higher airborne sound insulation performance.

The time taken to undertake sound testing varies from project to project as no site is exactly the same. Taking into account standard site conditions a set of tests on houses -two airborne walls will take one to two hours. A six pack of tests on flats – 2 airborne wall tests will usually take between one and two hours, although this is dependent on our engineers having full free uninterrupted access between all the units/rooms under investigation.

If you require sound insulation testing, or acoustic design advice then please contact us now at info@aptsoundtesting.co.uk  or phone me (Darren) directly on 07775623464.

Good Acoustic Design for Sound Testing

Good Acoustic Design for Sound Testing

To attain the standards stipulated within Building Regulations Part E, careful consideration should be shown to your buildings acoustic design  from the start of the project; however this requires different construction techniques and acoustic design detailing for new and build and conversion projects. With new build properties you have a blank canvas in terms of the overall design whereas conversions usually require you to work with the existing construction which can be quite difficult if the existing construction is not acoustically robust.

sound_transmission_through_floors

To try and overcome the problems with attaining Part E for your conversion project, we now offer an acoustic design package, which contains the following elements:

  1. Sample Sound Testing – of the existing construction. This offers an accurate overview of the acoustic performance of the existing partitions; this enables us to offer a targeted acoustic design using the sound insulation performance of the existing construction.
  2. Acoustic Design Review – a full design review of the proposed developments party walls and floors taking into account the performance characteristics of the existing construction as well as the buildability and materiel cost of the acoustic upgrade.
  3. Site Survey Visits – to let us view the existing site construction. This allows us to check for potential problematic construction such as inclusion of lightweight blocks in the existing construction. It also lets us check that the installation teams are installing the acoustic materials as per manufacturer’s guidelines.
  4. Final Precompletion Sound Testing  – in compliance with Building Regulations Part E to help achieve building control sign off.

We have undertaken hundreds of design reviews around London and the South East with our clients achieving  a 100% pass rate where the acoustic review has been followed. If you would like some more information in regards to our acoustic services and/or sound testing services please visit our website at info@aptsoundtesting.co.uk, or contact us at: info@aptsoundtesting.co.uk or call me (Darren) direct on 07775623464.

 

Sound Testing for Compliance with Lease Conditions

Sound Testing for Compliance with Lease Conditions

If you own or manage an apartment it has a lease agreement that has conditions relating to the changing of the floor construction, then you may require Sound Testing for Compliance with Lease Conditions. We undertake many leaseholder sound tests throughout London and the South East and offer a ‘4 step acoustic package’  to satisfy your lease conditions comprising of the following:

  1. Sample Sound Testing of the existing construction. This offers an accurate overview of the acoustic performance of the existing floor partition/s prior to the commencement of construction works. It also enables us to offer a targeted acoustic design using the sound insulation performance of the existing construction.
  1. Acoustic design review – once we have the performance figures from the sample sound testing have been established, we can forward a design that should improve the performance of the existing floor partition – even if you are changing the floor from a carpet to engineered timber floor finish!
  1. Site Visit – This allows us to check that the installation team is installing the acoustic materials as per manufacturer’s guidelines.
  1. Final Precompletion Sound Testing in-line with Approved Document E. This provides an accurate overview of the acoustic performance of the upgraded partition/s, the results of which can be handed over to the relevant person for sign off.

In most cases complaints are usually raised from impact noise such as foot fall from hard bottomed shoes etc. this is accentuated when the unit above has changed their floor finish from carpet to wood.

Sound_Insulation_Testing_Equipment

If you think you may have a problem with sound in your dwelling and or you have encountered complaints from a neighbour due to modifications you have made to the floor partition then please contact us now we can provide our ‘3 step plan’ to satisfy your units lease conditions, then please contact us now at: info@aptsoundtesting.co.uk  or phone Darren directly on 07775623464.

The Difference Between Laboratory and Site Sound Testing

The Difference Between Laboratory and Site Sound Testing

Many suppliers of acoustic insulation products quote laboratory sound test results  to demonstrate the performance of their systems. This often causes considerable confusion regarding how well products will perform as there are usually large differences between the laboratory and site conditions. For instance laboratory sound tests do not take account of flanking sound and therefore produce sound insulation figures that would be very difficult to achieve on site.

sound testing

Despite site contractor’s best endeavours, it is extremely difficult to build to the stringent exacting standards of the test laboratory. When the construction assembly is undertaken in the lab, it has gone through an exacting installation technique prior to the sound test, which is also a contributing factor why better sound testing levels are achieved.

Throughout the acoustic installation the manufacturer’s guidance is followed to the letter by the lab technicians. Although, this should be replicated on site, it seldom is due to time constraints etc. and so a design which can be easily in excess of the requirements of approved document E, can often lose approx. 8-10dB compared to the laboratory results. Unfortunately there may be many reasons for poor sound test results such as poor quality site installation as well as other on-site issues where cost, time and programming constraints may come into play.

architect drafting a house blueprint

architect drafting a house blueprint

One important thing to consider is that most building structures will be subject to varying amount of flanking sound, so field sound test data should show the real performance of a system in a building. Laboratory sound insulation tests simply measure sound and do not account for flanking sound transmission.

If you are worried about your projects acoustic design and/or have questions about the precompletion sound testing, please don’t hesitate to contact us now at: info@aptsoundtesting.co.uk or Darren direct on 07775623464. 

How to Improve your Sound Test Results

How to improve your Sound Test Results

If you have started a new or conversion development, it is important that from the offset you realise that you will need to comply with stringent sound insulation requirements of Approved Document E. Both new and converted residential dwellings use must meet the standards stipulated in Approved Document E. Part E states that the separating floor partition (floor between two separate dwellings) must achieve sound insulation figures of 45dB for airborne sound and 62dB for impact sound on all new builds and 43dB for airborne sound and 64dB for impact sound on converted dwellings; if you don’t achieve the aforementioned results then you will pass the sound testing. 

Building Control will expect you to demonstrate compliance with Approved Document E 2003 by undertaking an independent sound insulation test to prove that you have met the standards for sound insulation between dwellings.

Sound_Insulation_Testing_Equipment

The sound testing must only be carried out by either UKAS or ANC approved companies. If the sound tests are not carried out by approved compaines then Building Control may not accept the sound test report and subsequently it may need to be undertaken again by an approved company costing more time and money.

We are UKAS accredited to undertake sound insulation testing as well as air tightness testing. We offer design advice to help our client achieve Part E sign off. In some cases clients instruct us to proceed with the sound testing, without having carried our any acoustic upgrades or remedial works often resulting in their partitions failing the sound test.

Sound_Testing_Semi_Detached_House

If you are worried about passing your sound testing in London at the first attempt please don’t hesitate to contact us now at: info@aptsoundtesting.co.uk or visit our website at: www.aptsoundtesting.co.uk or call Darren Direct on 07775623464.

Reducing the Chance of Sound Testing failures

Reducing the Chance of Sound Testing failures

The simplest way to reduce the chance of sound testing failures is through careful consideration to the acoustic design at the start of the project.  Unfortunately, by simply specifying high performance wall and floor partitions, it is no guarantee to adequate sound isolation and successful sound testing at the end of the project.

We offer preconstruction design advice to help you achieve successful sound testing in-line with Building Regulations Part E. We also offer onsite inspection services to ensure that the sound insulation elements are being installed as per manufactures guild-lines, as it’s no use having good acoustic design if it not being installed properly on site.

architect drafting a house blueprint

Acoustic Design of Wall and Floor Partitions

The first stage of the acoustic design is to send through the design drawings – to include sections etc. We then review the design to check that the construction details proposed are capable of passing the sound tests. This usually takes place straight after planning has been approved as increased cost savings can be realised at the earliest stage, we will evaluate the construction methods and materials specified to ensure that they are capable of meeting the acoustic requirements of Approved document E. The typical areas we check are:

  1. There are no flanking points, where isolated partitions are wrongly mechanically fixed together to caused noise bridging.
  2. The walls and floors design are acoustically robust, to comply withBuilding Regulations Part E.
  3. The acoustic treatments for Soil Pipes, Stair Cases Steel Beams etc. to ensure they are acoustically fit for purpose, as these are some of the areas that get usually missed.
  4. Acoustic floor treatments are compatible with the proposed floor finishes i.e. Carpets, Laminates, Floor Tiles and under floor heating systems.

APT Sound Testing also provide on-going design support service, so you will have direct contact with the allocated acoustician from the start of the process through to the successful completion of the project. One of the most important services is the going site survey visits which allow our clients to feel confident about the outcome of testing at the end of the build. The site visits let us check that the installation teams are installing the acoustic materials as per manufacturers avoiding crucial onsite mistakes. You can often have a compliant design which still fails due to poor workmanship; the site survey visits negate the risk of sound test failure.

We also offer an acoustic advice service for clients that have failed their precompletion sound testing. We offer simple solutions to reduce the noise levels and achieve compliance with Part E. We can supply simple easy to follow acoustic design reviews, utilising our extensive knowledge of different materials and construction methods

If you require more information about acoustic design and/or sound testing on your project, please contact us now at info@aptsoundtesting.co.uk or call Darren direct on 07775623464.

Sound Intrusion Though Windows

Sound Intrusion Though Windows

Sound intrusion though windows can also be a source of great annoyance if the sound is excessive, and in some cases developments have failed the sound insulation testing due to poorly specified and installed windows. Sound intrusion may be down to a variety of factors. If the windows are operable types, the first thing to check is to see if the widows close properly against their seals and any weather stripping is continuous and in good order. If the window leaks air, then more often than not it will usually leak sound. If the window closes to form a tight seal and the weather-stripping seems adequate the next thing to check is the window frame. Windows are frequently installed in to the wall opening with plastic shims to insure the unit is plumb and level. In high traffic areas you will normally require a double glazed unit as a minimum and in some cases a triple glazed unit will be required.

Sound_Intrusion_Through_Windows

The space between the frame and the wall should be insulated and sealed before the window casings are installed. If this was not done correctly you can probably detect the sound leakage by placing your ear close to the frame and listening. The sound may be able to run along the cavity and back into the adjacent property, It is case of letting your ears do the walking and listening. If you detect distinguishable differences in sound you may have found the problem; the solution will be to remove the casing and insulate and caulk all leaks. In some cases the thickness of the glass maybe the problem in which case it may be necessary to install another layer of glass on the inside of the existing frame making sure that the additional pane of glass is well sealed into the opening.

In some instances you may be able to lower excessive sound by installing a heavy curtain – especially if the house is in a conservation area and as a result the local authority will not let you change or upgrade the windows.

If you require more advice on your project and/or you require precompletion sound testing, please contact us at: info@aptsoundtesting.co.uk  or phone me directly on 07775623464.

Remedial action following a sound insulation test failure

Remedial action following a sound insulation test failure

If a partition fails a sound insulation test, it can be difficult to provide definitive guidance on resolving specific problems that have occurred in individual buildings as the building is usually complete at the time of testing. However, using our knowledge of acoustic construction and detailing APT Sound Testing are usually able to identify and resolve any problems with the acoustic partitions.

ACOUSTIC_DESIGN

If the sound testing failure is attributed to the construction of the separating and/or associated flanking elements, other rooms that have not been tested as part of the testing schedule may also fail to meet the test performance levels. Additional tests may be needed, over and above the number recommended under Building Regulations Part E.

Extra sound testing will assist in identifying, at an early stage, where the failures have been caused by intermittent poor workmanship and/or design. Sound Testing may then be required for all plots to identify the ones that require remedial treatment. Where failure is due to a design fault, additional testing may not be required, as all plots with the same design are likely to require remedial treatment and so a generic acoustic upgrade can be undertaken to the failed partitions and then retested thereafter.

sound testing

To try and negate potential problems with the sound insulation testing we offer the following 4 step acoustic design advice package:

  1. Site Survey Visits – to let us view the existing site construction. This allows us to check for potential problematic construction detailing and also lets us check that the installation teams are installing the acoustic materials as per manufacturer’s guidelines.
  2. Sample Sound Testing – of the existing construction. This offers an accurate overview of the acoustic performance of the existing partitions.
  3. Design Review – a full design review of the proposed developments party walls and floors.
  4. Pre-completion Sound Testing to satisfy Approved Document E.

APT Sound Testing can supply a ‘one stop’ solution for all your acoustic requirements. If you would like more information in regards to sound insulation testing or acoustic design please contact us at: info@aptsoundtesting.co.uk  or call Darren direct on 07775623464.

Sound Test Report Information

Sound Test Report Information

All our testing and reportage are undertaken in strict accordance with Annexe B of Approved Document E of the Building Regulations and BS EN ISO 140-4:1998 “Field measurements of airborne sound insulation between rooms” and BS EN ISO 140-7:1998 “Field measurements of impact sound insulation of floors.”

Acoustic_Design_Service

After the sound insulation test a sound test report or certificate should be provided in compliance with Building Regulations Part E. This normally provides the following information:

  1. The company name and/or testers name and address that carried out the test and the accreditation held by the membership organisation.
  2. The client/applicant name.
  3. Site address.
  4. Plots tested
  5. If it was a wall or floor test.
  6. List of equipment used (including details on calibrated equipment) and testing technique.
  7. Confirmation that the test was in accordance with BS EN ISO 140 Part 4 (airborne) and Part 7 (impact).
  8. Measurement procedure.
  9. The results should be calculated in accordance with BS EN ISO 717-1 and 717-2 1997. Detailed test results giving a declaration of a pass or fail.
  10. Date of test. The test results or certificates will be submitted to the verifier during the completion certificate process.

The test duration depends on the amount of sound insulation tests required on the project. Taking into account standard site conditions a set of two airborne wall tests (for a pair of houses) will take one to two hours. A six pack of tests on flats, consisting of two airborne walls, two airborne floor and two impact tests will take between two to three hours. Throughout the sound testing we will require full free uninterrupted access to the units/rooms in all test areas.

We offer an acoustic design service to review the construction detailing. We also offer a sample testing service along with site inspections which provides a ‘one stop acoustic solution’. We visit site during the build process to check for any workmanship issues that may cause problems during the final pre-completion sound testing.

If you would like APT Sound Testing to review your sites acoustic construction, then please speak to us about our acoustic design service, alternatively if you just require sound insulation testing please contact us at: info@aptsoundtesting.co.uk