Preparing Your Project For Sound Testing

Preparing Your Project For Sound Testing

There are many important things to remember as you near completion on your project, one of which is to adequately prepare your London project for Sound Testing. This means that the dwellings and the ‘habitable rooms’ i.e. living rooms and bedrooms should be the final finishing stage – usually a week or two prior to completion.

Sound_Insulation_Test_London

To help our clients prepare for compliance with Approved Document Part E throughout London, we have provided a site preparation checklist – shown below. It’s worth noting that where items are not in place this will negatively affect the sound insulation performance of the dwellings:

  1. Internal & external doors and windows must be hung, glazed & close-able on the latch.
  2. Trickle vents and other ventilation systems should be fitted and closed.
  3. All wall, floors & ceiling constructions must be completed
  4. Skirting boards and cornice should all be completed
  5. Electrical sockets, TV Aerial sockets & light switches should be fitted
  6. Rooms must be clear of building materials, tools & unfurnished
  7. No cosmetic floor coverings should be fitted (i.e. laminate, carpet, vinyl, ceramics)
  8. No noisy operations such as drilling, cutting or ground-works to occur nearby during testing
  9. Provision of 240v 50Hz mains power is required within all the dwellings under test 110v cannot be used.

To attain compliance with Approved Document E one set of tests needs to be undertaken for every ten flats or houses provided the construction system is the same. A set means that the test should include two locations where the party element (wall or floor) is tested. This is equivalent to two individual tests when assessing the performance of a wall – airborne performance only) and four individual tests when assessing a floor (two airborne and two impact tests).

All sound insulation tests must be undertaken between habitable spaces (e.g. bedrooms, living rooms) and not to or from common spaces such as stairwells and corridors. Approved Document E 2003 states that a minimum of 10% of all party walls and floors is sound tested for every construction group or sub-group; however, where variations in the construction such as a different wall and/or floor type then further testing may be required.

APT Sound Testing provides a full range of Sound Testing in London in compliance with Approved Document E. if you would like more information please contact us at info@aptsoundtesting.co.uk or call me direct on 07775623464.

Sound Testing on Conversion Projects

Sound Testing on Conversion Projects

In our experience acoustic design and sound testing on conversion projects don’t need to be problematic. If you are currently in the process converting offices and/or houses info flats or ‘Rooms for Residential Use’, then its very important that the acoustic design is embraced from the start of the project.

Air Pressure Testing  have many years of experience in providing acoustic design and sound insulation testing in a comprehensive package designed to help you meet the legal requirements of Building Regulations Part E.

Acoustic Design Advice

As a  multi UKAS accredited company, you can be sure that all our services are undertaken to the highest laboratory standards. The types of projects that need to comply with Approved Document E for conversion projects or ‘Rooms for Residential Use’ are:

  1. House to flat conversions
  2. Commercial building to flat conversions.
  3. Hotels and hostels
  4. Boarding houses
  5. Halls of residence
  6. Residential homes

We can offer you the following services to help your development comply with Approved Document E:

  1. We review the architect’s drawings to check the required acoustic principles have been followed and meet the requirements of Approved Document E.
  2. We undertake a site visit and analyse the current state of building construction. And to check there are no site specific construction problems that may affect the acoustic performance of the building.
  3. We under take sample sound testing to check the sound insulation properties of the buildings existing floors and walls.
  4. We will provide you with a full and detailed acoustic design report that outlines which acoustic treatments taking into account the most cost and buildability.
  5. We will provide ongoing support and site visits to assist the builder/consultant to ensuring that the level of detail required is met and deal with any ongoing issues that may arise.
  6. We will undertake the final precompletion sound testing to achieve compliance with Approved Document E.

We’ve successfully guided our clients through hundreds of different conversion projects helping our clients achieve compliance with Approved Document E.

If you would like advice on your acoustic design or sound testing in London, please contact us now at info@aptsoundtesting.co.uk or call us on 07775623464.

Airborne and Impact Sound Tests

Airborne and Impact Sound Tests

You are required to undertake two types of sound testing to comply with Building Regulations Part E, they are Airborne and Impact sound tests. Airborne sound tests are undertake on wall and floors and impact tests are undertaken on floor only.

To test the sound insulation properties of a floor or wall via airborne sound testing, you need to provide a sound source which consists of an amplifier and loud speaker is set up on one side of the wall or floor partition that is to be tested. We then turn the setting to turn on Pink noise. Pink noise sounds like the static that can be heard on a radio that is off station. Pink noise is used  because it is made up of a wall of sound that has a wide spectrum of frequencies. This provides an indication of sound insulation performance for a wide range of sounds that may be experienced within a dwelling from musical instruments to loud TV noise sources.

sound testing

The pink noise is measured in the room which contains the speaker or sound source using a Class 1 Norsonic sound level meter; thereafter the noise is measured on the other side of the wall or floor partition that is being tested. In layman’s terms the difference between these two levels is the amount of sound that is stopped by the sound insulating qualities if the wall or floor partition/s. The result is then corrected and adjusted depending on the echo or reverberation time within the receiving room, and any background noise such as builders work noise etc.

To test the impact sound insulation performance of a floor, a Norsonic tapping machine which consists of five small hammers that are dropped onto the floor to simulate foot fall, is placed on the floor. The resultant noise in the room below is measured with a Norsonic Class 1 sound level meter and the amount of noise that passes through the floor is the impact sound transmission level and is expressed as a single number. This result is then corrected and adjusted depending on the reverberation time of the rooms as well as any background noise to give the impact sound transmission result (LnT,w).

Impact Sound Testing

Both types of sound tests results are then compared to the performance criteria of Approved Document E, which stipulates that airborne sound needs to achieve 45dB for new build & 43dB for conversion projects. To achieve a pass for impact sound testing you need to achieve 62dB for new build & 64dB conversions.

If you have a project that’s needs acoustic design advice or needs precompletion sound testing then please contact us at: info@aptsoundtesting.co.uk or call us directly on 07775623464.

Sound Testing Services for New Dwellings

Sound Testing Services  for new dwellings

Sound Testing Services became mandatory in England & Wales in 2003, when Approved Document E was updated. Approved Document E requires new and converted to achieve a reasonable level of sound insulation between dwellings. The easiest way simplest way to comply with the requirements of Approved Document E; is to have on-site pre-completion sound insulation testing carried out on your project.

Many of our clients are clients are apprehensive prior to having to undertake pre-completion sound insulation tests.  This is often down to the fear of failure; however if the the acoustic design specification has been undertaken from the offset of the project and is closely followed during the construction phase then he chance of potential failure is greatly reduced.

sound testing equipment

Approved Document E requires a minimum of one ‘set’ of tests for every ten units in each group and/or sub group.  This is usually broken down to two airborne wall, two airborne floor and two impact sound tests. If you have a development of 25 houses, with five different sub-groups (5 units in each) then you would usually conduct 5 ‘sets’ of tests.  If no separating floors are available, i.e. in semi-detached or terraced houses, one set of tests would consist of two airborne tests of separating walls only.

If the precompletion test results do not satisfy the performance criteria of Approved Document E, then our test engineer will attempt to determine the possible causes of failure. This may be to do with construction detailing around services or at junctions, or simply, poor acoustic design. Once a specific reason for failure has been determined, we can then advise the client on remedial actions that can be undertaken.

If you have a project that’s needs acoustic design advice or needs precompletion sound testing then please contact us at: info@aptsoundtesting.co.uk or call us directly on 07775623464.

Successful Sound Testing in London

Successful Sound Testing in London 

From the offset careful consideration should be shown to the acoustic design detailing for both conversion and new build projects if you are to achieve a successful sound testing in London at the first attempt.

For instance many of the dwellings in London consist of flats converted from large Victorian houses. At the time of the original build some 100 years ago, designing for sound insulation was not a consideration and so many of the dwellings suffer from adverse noise transference between the floor and wall partitions. This can be extremely stressful to the occupant’s well-being is a major cause for concern.

ACOUSTIC_DESIGN

There are ways to improve the airborne and impact performance by improving the wall/floor partitions ability to reduce the amount of sound transmission from one side of a construction element to the other and subsequently  from dwelling to dwelling. By adding isolation and  mass to the floors and wall construction compliance with Part E for conversion projects can be achieved.

To help our clients achieve successful sound testing we offer the following ‘3 step package’:

  1. Sample Sound Testing of the existing building. This offers an accurate overview of the acoustic performance of the existing partitions which enables us to offer a targeted acoustic design using the sound insulation performance of the existing construction.
  2. Acoustic Design Review of the proposed developments party walls and floors to ensure acoustic details with be sufficient to pass Building Regulations Part E
  3. Site Survey Visits to check that the onsite construction is being undertaken in-line with manufacturer’s guidelines.

In our experience if the acoustic design is taken into consideration from the offset of the project, then it usually results in compliance with Building Regulations Part E.  In many cases sound test failure is down to poor acoustic design and poor workmanship, that is why we offer the 3 step process to achieve successful sound testing on your London project.

If you have a project that requires acoustic design advice or sound insulation testing, then please contact us at: info@aptsoundtesting.co.uk or phone us directly on 07775623464.

Sound Testing Terminology (2 of 3)

Sound Testing Terminology (2 of 3)

Often confusion can arise from the large amount of ‘terms’ used in conjunction with acoustic design and sound insulation testing. To help with this we have made a list of the following terms for clarity – this is the second of three blogs:

Façade Testing  – This Standard – ISO 140-5:1998) specifies the testing methods to evaluate the sound insulation in buildings and building elements for facades. Three rounds of a proficiency testing scheme for airborne sound insulation measurements have been performed according to the methods specified in the standard for a whole facade by using an external loudspeaker as the noise source.

sound testing equipment

Flanking element (flanking wall) – This is any building element that contributes to the airborne sound or impact transmission between rooms in a building which is not the direct separating element (i.e. not the separating wall or separating floor).

Flanking strip or edge strip – This is a resilient strip using foamed polyethylene normally 5 mm thick, which is located at the perimeter of a floor to isolate the floor boards from the walls and skirting.

Flanking transmission  – This is airborne or impact transmission between rooms that is transmitted via flanking elements and/or flanking elements in conjunction with the main separating elements. An example of a flanking element is the inner leaf of an external wall that connects to the separating ‘core’ of a wall or floor.

Flexible closer – This is a flexible cavity stop or cavity barrier which seals the air path in cavities linking adjoining dwellings.

Floating floor treatment (FFT) – This is a timber floating floor system which may use battens, cradles or platform base, all of which use a resilient layer to provide isolation from the base floor and adjacent wall elements.

Gypsum based plasterboard  – This is a dry lining board applied to walls, ceilings and within floating floor treatments which has gypsum content. It may also have fibre reinforcement within the board.

Impact sound – This is sound which is propagated from a noise source through a direct medium. An example of this is footfall on a floor.

Impact sound transmission – This is sound which is spread from an impact noise source in direct contact with a building element.

We hope the above information in regards to Sound Testing Terminology has been helpful. If you would like more information in regards to acoustic design and sound testing services, please contact us at info@aptsoundtesting.co.uk or visit our website at: www.aptsoundtesting.co.uk

Broken Down Rating Methods for Sound Testing

Broken Down Rating Methods for Sound Testing 

The sound insulation rating methods that follow are defined in:

Sound insulation testing is usually undertaken near the end of a project to show that the party wall and floor partitions meet the standards shown in Building Regulations Approved Document E.  The method for testing for airborne and impact sound insulation is in full accordance with: the suggested methods presented in BS EN ISO 140-parts 4 & 7: 1998. Sound tests are broken down into various rating methods.

sound testing equipment

The sound insulation rating methods that follow are defined in:

 Rating Method – RW

This single figure rating method is the rating used for laboratory airborne sound insulation tests. The figure indicates the amount of sound energy being stopped by a separating building element when tested in isolation in the absence of any flanking paths.

 Rating Method – DnTw

The single figure rating method that gives the airborne sound insulation performance between two adjacent rooms within a building as measured within site conditions. The result achieved is affected not only by the separating element also by the surrounding structure and junction details.

 Rating Method – Ctr

The Ctr adaptation term is a correction that can be added to either the RW (laboratory) or DnTw (site) airborne rating. The Ctr term is used because it targets the low frequency performance of a building element and in particular the performance achieved in the 100 – 315 Hz frequency range. This term was originally developed to describe how a building element would perform if subject to excessive low frequency sound sources, such as traffic and railway noise. This rating is expressed as RW + Ctr and allows the acoustic designer to critically compare performances. The rating method has not been universally welcomed. Some

acousticians believe that the method is too crude as it only considers the low frequency performance, and because site measurements at low frequencies are prone to difficulties, which can lead to a lack of confidence in the results achieved.

 Rating Method – Lnw

This single figure rating method is the rating used forclaboratory impact sound insulation tests on separating floors. The figure indicates the amount of sound energy being transmitted through the floor tested in isolation, in the absence of any flanking paths. With impact sound insulation, the lower the figure the better the performance.

Rating Method – LnTw

The single figure rating method that is used for impact sound insulation tests for floors. The figure indicates the sound insulation performance between two adjacent rooms within a building as measured on site. The result achieved is affected not only by the separating floor but also by the surrounding structure, e.g. flanking walls and associated junction details.

Rating Method – Dncw

The single figure laboratory rating method, which is used for evaluating the airborne sound insulation performance of suspended ceilings. Laboratory tests simulate the room-to-room performance of the suspended ceiling when a partition is built up to the underside of the ceiling with sound transmitted via the plenum.

APT Sound Testing can advise on all types of acoustic design, whether it’s accomplished during initial construction or during a refurbishment/renovation project.  We have the technical experience to help identify and rectify your soundproofing or noise control problem.

If you would like more information in regards to sound testing please follow our blog at: http://soundtestinguk.blogspot.co.uk or contact us at: info@aptsoundtesting.co.uk or visit our website at: www.aptsoundtesting.co.uk

Noise Flanking Through Steel Columns

Noise Flanking Through Steel Columns.

Unless Steel Columns or beams are isolated from the surrounding wall/floor partition it can lead to noise flanking, particular hollow steel columns. Steel can also provide a strong path for structural impact transmission due to its dense nature.

Pre-conversion sample sound tests should be able to identify whether any columns act as a significant transmission path and whether any acoustic treatment is required to remedy the situation. It may not be necessary to treat the column in all dwellings if flanking is limited, however in many instances the columns will need to be acoustically boxed to prevent sound test failure.

ACOUSTIC_DESIGN

One such acoustic treatment for steel columns or beams would be to construct a free standing metal or timber stud partition around the column, incorporating 50mm insulation quilt and sheeted with two layers of gypsum-based board. Where columns pass through separating floors, as in old bonded warehouses, the junction between column and floor should be well sealed not only for sound insulation but also for fire. The column linings should be double lined with gypsum-based board (minimum mass per unit area 10kg/m2).

Timber beams do not significantly affect the sound insulation performance of a separating floor. However, if a beam has been installed for strengthening, the boxing around the beam may be a single sheet of lightweight board and the board may be fixed directly to the beam resulting in a noise flanking path for airborne and impact sound. This can be resolved by stripping off the boxing, packing any voids with dense mineral wool batt and re-sheeting with two layers of dense gypsum-based sound board.

We hope the above information helps you to understand the potential problems with acoustic design and pre-completion sound testing on your development. If you have a project that’s requires acoustic design advice or sound testing in London, then please contact us at: info@aptsoundtesting.co.uk  or phone us directly on 07775623464.

The two types of sound insulation testing through floors.

There are two distinct types of sound insulation testing through floors, they are:

  1. Airborne Noise (for example speech and music)
  2. Impact Noise (for example footsteps directly on the floor above)

In the event of  both types of sound – Airborne & Impact) are emitting excessive noise through the ceiling/floor, then there are some easy installations that should reduce the sound levels and improve your sound test results.

sound testing equipment

We also offer an acoustic design service which helps clients to pass the sound testing upon completion of the acoustic upgrade. By advising on a simple cost effective wall and/or floor upgrade, we are able to forward simple to follow acoustic design reviews, utilising our extensive knowledge of different materials and construction methods. Where our acoustic upgrades have been incorporated into the site construction, all the pre-completion sound tests have passed, ensuring compliance with Part E of Building Regulations.

Pre-completion sound testing has been a mandatory requirement since 2003 and all new build properties and conversions which were built after this date require 10% of each party wall/floor construction type to be tested. In is usual to test between living rooms and bedrooms as these are classed as the two main habitable rooms; however, other rooms can be used if this is not possible such as study’s, kitchens and dining rooms.

We also carry out a large amount of sound tests in council/housing association blocks, where the residents are experiencing excess noise between the dividing wall and floor partitions.

We provide full UKAS accredited air and sound testing in London, using the latest Class 1 equipment, so our clients can be sure that all testing is completed to a strict ISO quality controlled standard

If you would like advice on your acoustic design or sound testing in London, please contact us now at info@aptsoundtesting.co.uk or call us on 07775623464.

Failed Sound Testing in London?

Failed Sound Testing in London?

When a building fails the Part E Sound Test in London it may be down to a problem with the acoustic construction, this may be down to issues such as noise flanking etc.

Ongoing problems with airborne and structure borne sound are often associated with direct noise flanking transmission through floors and supporting walls and other associated structures such as the external envelope. One common cause of noise flanking and failed sound testing is often associated with the inclusion of lightweight blocks within the construction of the building envelope and/or blocked cavities. It all cases it is essential to establish if your problem is due to direct transmission, flanking transmission or a combination of both so that the most cost effective remedial treatment can be chosen.

Sound Testing in London

Unwanted noise travelling along flanking paths will make the building structure vibrate which causes the sound to radiate into your room. One simple cost effective solution is to build another wall or ceiling in front of the original, but not connected to it (often called an independent wall or ceiling) so it provides isolation between materials.

One way to reduce the chance of flanking transmission is through careful consideration to the design at the start of the project.  Unfortunately, by simply specifying high performance wall and floor partitions it is no guarantee to adequate sound isolation and successful sound insulation testing. APT Sound Testing offer both preconstruction and post construction design solutions to achieve a successful sound testing in-line with Part E of Building Regulations. We also offer onsite inspection services to ensure that the sound insulation elements are being installed as per manufactures guild-lines. Even if both types of sound are emitting through the ceiling/floor then there are some easy installations that should reduce the sound levels and improve your sound test results. By advising on a simple cost effective wall and/or floor upgrade, we are able to forward simple to follow acoustic design reviews, utilising our extensive knowledge of different materials and construction methods

If you have failed a sound test and need acoustic advice on how to overcome the problem then please contact us at info@aptsoundtesting.co.uk or call me direct on 07775623464.