Acoustic Design Advice for my Sound Insulation Test

Acoustic Design Advice for my Sound Insulation Test

We at APT Sound Testing pride ourselves on offering a comprehensive acoustic design service to help you development attain compliance with Building Regulations Part E at the first attempt. If you send through the relevant drawings such as sections and floor plans during the design stages of the project, we can check the design is adequate and if there appears to be any junctions or details where ‘noise flanking’ may occur, we can then advise if any changes are required to lower the chance of sound test failures.

Acoustic_Design_Service

There are many factors to consider when considering good acoustic design, and they are usually split up into five key factors. If used together or in various combinations they will improve sound insulation properties over a wide range of frequencies. The main factors are:

  1. Mass
  2. Isolation
  3. Absorption
  4. Resilience
  5. Stiffness

Coupled_wall_construction

Also, noise flanking transmission may in some cases be the dominant pathway between adjoining dwellings, especially in existing buildings where you are planning to convert offices/large houses into flats. Here are just a few of the potential noise flanking areas:

  1. Structural Steels
  2. Windows built very close to Internal partitions
  3. Inner leaf of the external wall
  4. External wall cavities
  5. External façade or outer leaf
  6. Roof structure

APT Sound Testing can advise on all types of acoustic design, whether it’s during the initial design of a new build project and/or undertaking sample sound testing and design during a refurbishment/renovation project. We also undertake UKAS accredited sound insulation testing providing a ‘one stop’ solution for all your acoustic requirements.

If you would like more information on our full range of our acoustic services please contact us now at info@aptsoundtesting.co.uk or call Darren direct on 07775 623464.

Upgrading Floor Partitions to Pass Sound Testing

Upgrading Floor Partitions to Pass Sound Testing

In our experience of undertaking hundreds of sample of sound tests throughout London and the Home Counties, refurbishment projects usually achieve 30-35dB for airborne sound and 70dB for Impact Sound, if the existing construction has not been acoustically upgraded. Unfortunately, the aforementioned figures do not meet the required 43dB & 64dB as stipulated in Part E of Building Regulations. As sound double every 10dB this is a massive failure and acoustic improvements must be made. Many existing construction consist of a similar construction as shown in as detail 1 below.

Detail 1: Existing Floor Partitions Rated at Approx. 30dB

Failed_sound_Testing_Due_to_existing_floor_Construction_

Improving Existing Floor Partitions

To reduce airborne and impact sound transmission this usually means adding density and isolation to the floor construction. This can be as simple as adding a drop ceiling consisting of 125mm timber frame. The top of the frame must be a minimum of 25mm below the existing ceiling finish – such as lathe and plaster. Then, to the inside of the timber frame add 100mm of Acoustic Wool and two layers of sound-board tacked to the bottom of the timber frame – all boards to be lapped. This should improve your sound test results by approx. 10-15dB depending on the existing site conditions and quality of the installation – as per Detail 2 below:

Detail 2: Acoustic Flooring Partition Upgrade

ceiling_upgrade_to_pass_sound_test

Taking the above into account is it essential that good acoustic design is addressed right from the start of the refurbishment project, so it prevents delays in handover, i.e. to prevent the dwelling failing the sound testing at building control signoff stage.– a common problem.

If you would like advice on your acoustic design or require sound insulation testing in London, please contact us now on 07775623464 or contact us at info@aptsoundtesting.co.uk.

 

Improving Sound Insulation on Conversion Projects

Improving Sound Insulation on Conversion Projects

In cities throughout the UK there are a huge amount of conversion projects where large Victorian or Georgian houses – or more recently office blocks) have been converted into flats or rooms for residential purposes. Unfortunately designing for sound insulation is not always shown the highest priority on these types of projects, so many converted dwellings suffer from adverse noise transference between the floor and wall partitions. This can be extremely stressful to the occupant’s well-being is a major cause for concern.

architect drafting a house blueprint

architect drafting a house blueprint

We have helped many of our clients achieve compliance with Part E, by undertaking some simple steps. We can undertake an initial sample sound test of the existing wall and floor construction to ascertain the existing sound insulation levels. Once we have established the sound levels for the existing construction, we can then look at extent of the acoustic upgrades to attain Part E Compliance. This is much more effective than just forwarding an acoustic design that may be to excessive and expensive, especially if the existing floor and/or wall only needs to improve by a minimal amount such as 1-3dB. By having the existing sound levels of the partitions we can recommend targeted, acoustic upgrades to comply with Building Regulations Part E.

Sound_Insulation_Testing_Equipment

=The sound insulation levels required to pass Part E for refurbishment projects are less stringent than new build projects. Instead of 45dB for airborne its 43dB (2 dB less), and for instead of 62dB for Impact Sound Testing its 64dB on new build (2 dB more).

Taking the above into account is it essential that good acoustic design is addressed right from the start of the refurbishment project, so it prevents delays in handover, i.e. to prevent the dwelling failing the sound testing at building control sign off stage.– a common problem.

We have offered design advice on hundreds of conversion projects, so we have the experience to help you comply with Building Regulation Part E and achive a sucsessful sound test. If you would like advice on your acoustic design or require sound insulation testing in London, please contact us now on 07775623464 or contact us at info@aptsoundtesting.co.uk.

 

HOW MANY SOUND TESTS DO I NEED ON MY PROJECT

HOW MANY SOUND TESTS DO I NEED ON MY PROJECT

Our clients often ask ‘how many sound tests do I need on my project’? Part E stipulates that one set of sound tests needs to be undertaken for every ten flats or houses, provided the construction system is the same, if it’s not then you may be required to undertake a set of tests on each type of construction.

A set means 6  sound tests, this should include two locations where the party element (wall or floor) is tested. This is equivalent to two individual tests when assessing the performance of a wall this means 2 airborne wall, 2 airborne floor and 2 impact sound tests as a minimum wherever possible. Wherever possible tests must be undertaken between habitable spaces (e.g. bedrooms and living rooms. Here is a quick summary of the amount of tests required per type of project.

Semi-Detached Houses:

On a pair of semi-detached houses, two airborne sound insulation tests on a pair of separating walls would be required.

Sound_Testing_Semi_Detached_House

Flats (Up to 10 flats)

On flats a 6 Pack would normally be required, this would usually comprise of two airborne sound insulation tests on separating walls; two airborne sound insulation tests of separating floors and two impact sound transmission tests of separating floors.

Sound_Testing_Flats

Rooms for Residential Purposes (up to 10 Rooms)

On student accommodation, hotel rooms & care homes a set of tests would usually comprise of one airborne sound insulation test of a separating wall; one airborne sound insulation test on a separating floor and one impact sound transmission test of a separating floor

Sound_Testing_Hotels

If you are unsure of the amount of sound tests required on your development, please contact us now at: info@aptsoundtesting.co.uk or call me direct on 07775623464.

Here is a link to our website www.aptsoundtesting.co.uk  which shows you our full range of services in compliance with the latest Building Regulations.

Tips to Pass your Sound Insulation Test

Tips to Pass your Sound Insulation Test

Our clients often get asked for tips in regards to passing their sound testing; here are a few tips to help you pass Building regulations Part E:

  • Ensure all penetrations are fully sealed where they terminate through floors and they are adequately boxed with acoustic quilt and two layers of plasterboard.
  • Avoid the use of lightweight blocks in the inner envelope construction as sound will travel both vertically and horizontally from dwelling to dwelling.
  • The use of resilient suspended ceilings will help improve the performance of the floor partition.
  • Ensure all support steels/timbers are carefully boxed out where they travel from flat to flat vertically and horizontally.
  • Use a high quality resilient acoustic membrane on top of the floor to improve the impact performance of a floor.
  • Ensure that you don’t position sockets back to back in acoustic partitions walls.

architect drafting a house blueprint

There are many factors to consider when considering good acoustic design, and they are usually split up into five key factors. If used together or in various combinations they will improve sound insulation properties over a wide range of frequencies. The main factors are:

  1. Mass
  2. Isolation
  3. Absorption
  4. Resilience
  5. Stiffness

Another potential problem can also be down to noise flanking transmission, especially in existing buildings where you are planning to convert offices/large houses into flats. Here are just a few of the potential noise flanking areas:

  1. Structural Steels
  2. Windows built very close to Internal partitions
  3. Inner leaf of the external wall
  4. External wall cavities
  5. External façade or outer leaf
  6. Roof structure

If you click on this link: http://blogyourbusiness.co.uk/designing-for-sound-testing-in-london/ it will take you to the corresponding article which should help explain this in more detail. Here is a link to our website www.aptsoundtesting.co.uk which shows you our full range of services in compliance with the latest Building Regulations. 🙂

If you would like more information on our acoustic services, please don’t hesitate to contact me at: info@aptsoundtesting.co.uk or call me (Darren) direct on 07775623464.

Good Acoustic Design for Sound Testing

Good Acoustic Design for Sound Testing

To attain the standards stipulated within Building Regulations Part E, careful consideration should be shown to your buildings acoustic design  from the start of the project; however this requires different construction techniques and acoustic design detailing for new and build and conversion projects. With new build properties you have a blank canvas in terms of the overall design whereas conversions usually require you to work with the existing construction which can be quite difficult if the existing construction is not acoustically robust.

sound_transmission_through_floors

To try and overcome the problems with attaining Part E for your conversion project, we now offer an acoustic design package, which contains the following elements:

  1. Sample Sound Testing – of the existing construction. This offers an accurate overview of the acoustic performance of the existing partitions; this enables us to offer a targeted acoustic design using the sound insulation performance of the existing construction.
  2. Acoustic Design Review – a full design review of the proposed developments party walls and floors taking into account the performance characteristics of the existing construction as well as the buildability and materiel cost of the acoustic upgrade.
  3. Site Survey Visits – to let us view the existing site construction. This allows us to check for potential problematic construction such as inclusion of lightweight blocks in the existing construction. It also lets us check that the installation teams are installing the acoustic materials as per manufacturer’s guidelines.
  4. Final Precompletion Sound Testing  – in compliance with Building Regulations Part E to help achieve building control sign off.

We have undertaken hundreds of design reviews around London and the South East with our clients achieving  a 100% pass rate where the acoustic review has been followed. If you would like some more information in regards to our acoustic services and/or sound testing services please visit our website at info@aptsoundtesting.co.uk, or contact us at: info@aptsoundtesting.co.uk or call me (Darren) direct on 07775623464.

 

Sound Testing to Comply with Lease Conditions

Sound Testing to Comply with Lease Conditions

Many people unknowingly fail to abide by the lease agreement as they may not know that there is usually a condition that states that they need to employ an acoustic company prior to making any changes to the floor of their apartment. The lease conditions often states that you need to undertake sound insulation testing prior to the commencement of works and upon completion of works.

In many cases their neighbour/s may complain that they can hear extra noise, this is often due to the fact that they may have changed the floor finish from carpet to wood. Unless extra acoustic design considerations are taken into account it usually results in an increase of extra airborne and impact noise being heard in unit below.

Sound_Testing_for_Lease_Agreements

Even if the floor assembly has been designed and constructed to provide adequate airborne isolation, impact noise can still be a major problem. If the finished floor surface had previously been carpet, the carpeting and underlay will normally provide a good degree of impact sound isolation. On the other hand, when the finished floor is floor is constructed in hardwood, stone or ceramic tile. Achieving good impact sound isolation requires much more attention.

If you think you may have a problem with sound in your dwelling and or you have encountered complaints from a neighbour due to modifications you have made to the floor partition then please contact us now. In all cases try be sure to describe the problem in as much detail as possible. Describe the nature of the sounds, when and where you or your neighbour can hear it. Is it impact noise or airborne noise or a combination of both? The more information you can provide us, the quicker we can try to determine the nature of the problem and subsequently find a solution.

In many cases, due to the complexity of acoustical and noise problems due to varying constructions, it is impossible to cover all problems in a short article such as this; however in our experience if we are employed from the beginning of a project, it usually results in compliance with Building Regulations Part E and /or compliance with your leasehold agreement, which may avert costly legal battles at the end of the project.

If you are about to make changes to your apartment, and you think you require acoustic design advice, then please contact us now at: info@aptsoundtesting.co.uk  or phone me directly on 07775623464.

 

Careful Acoustic Installation leads to Successful Sound Testing

Careful  Acoustic Installation leads to Successful Sound Testing

It is very important that acoustic installation details are closely followed to ensure that the onsite results are as close as possible to the laboratory target. It is pointless having good acoustic design detailing if this is not carefully followed on site.

Acoustic_Design_Service

The following list explains what should during the onsite construction process to achieve a successful onsite sound tests and Part E compliance:

  1. Ensure that the construction team is fully briefed of the acoustic details.
  2. Ensure that the manufactures installation booklet is on site at all times.
  3. Ensure that the Acoustic floor is fitted with staggered joints.
  4. If you are installing floating screed ensure all isolation layer joints are overlapped and taped.
  5. Ensure all the Acoustic floor is sealed watertight even around heating pipes.
  6. Do not nail or screw through an Acoustic Floor.
  7. Do not screws plaster board into joists, when using a Resilient Bar system.
  8. Ensure the insulation fills the whole width of void
  9. Pack around pipe work and double board with staggered joints.
  10. Ensure that the plasterboard on any walls is complete right down to within 5-10mm of the subfloor and seal all gaps.
  11. Ensure you use the isolation tape around the wall of each room.
  12. Ensure plasterboard is fitted with staggered layers and all joints sealed.
  13. If using Resilient Bars ensure that they are fitted as per manufacturer’s recommendations.
  14. Ensure all Fireplaces are blocked up with brick or a twin lined plasterboard system and filled with acoustic insulation.
  15. Ensure that any RSJ’s or supporting steel work is insulated and isolated from plasterboard.
  16. Ensure all waste pipe service runs are boxed in with insulation and plasterboard.
  17. Ensure all doors and windows are installed before the test is carried out, to stop noise transference.

We offer an acoustic design service which includes site visits to make sure the acoustic elements are being installed as per the manufacturer’s guidelines. If you are worried about passing your sound testing at the first attempt please don’t hesitate to contact us now at: info@aptsoundtesting.co.uk or call Darren Direct on 07775623464.

The Difference Between Laboratory and Site Sound Testing

The Difference Between Laboratory and Site Sound Testing

Many suppliers of acoustic insulation products quote laboratory sound test results  to demonstrate the performance of their systems. This often causes considerable confusion regarding how well products will perform as there are usually large differences between the laboratory and site conditions. For instance laboratory sound tests do not take account of flanking sound and therefore produce sound insulation figures that would be very difficult to achieve on site.

sound testing

Despite site contractor’s best endeavours, it is extremely difficult to build to the stringent exacting standards of the test laboratory. When the construction assembly is undertaken in the lab, it has gone through an exacting installation technique prior to the sound test, which is also a contributing factor why better sound testing levels are achieved.

Throughout the acoustic installation the manufacturer’s guidance is followed to the letter by the lab technicians. Although, this should be replicated on site, it seldom is due to time constraints etc. and so a design which can be easily in excess of the requirements of approved document E, can often lose approx. 8-10dB compared to the laboratory results. Unfortunately there may be many reasons for poor sound test results such as poor quality site installation as well as other on-site issues where cost, time and programming constraints may come into play.

architect drafting a house blueprint

architect drafting a house blueprint

One important thing to consider is that most building structures will be subject to varying amount of flanking sound, so field sound test data should show the real performance of a system in a building. Laboratory sound insulation tests simply measure sound and do not account for flanking sound transmission.

If you are worried about your projects acoustic design and/or have questions about the precompletion sound testing, please don’t hesitate to contact us now at: info@aptsoundtesting.co.uk or Darren direct on 07775623464. 

Why Have I Failed my Sound Insulation Test?

Why Have I Failed my Sound Insulation Test?

This is one of the most common questions clients ask when their property has just failed the sound testing. One of the main reasons for acoustic partitions failing the Part E sound test is often down to poor isolation of material/s, which can lead to excessive noise flanking. Noise Flanking is a term used by acoustic engineers to describe where sound passes through an acoustic partition due to the abutment of materials. The noise simply hits the one side of the wall and then travels through the construction via a noise bridge. This can be areas such as the incorrect use of masonry wall ties i.e. solid fishtail ties, used in place of specified acoustic wall ties; if your building suffers from noise flanking it may result in a sound test failure.

Sound_Insulation_Testing_Equipment

Unwanted noise travelling along flanking paths can make the building structure vibrate, which can cause sound to radiate into your room – as shown in the plate below . One simple cost effective solution is to build another wall or ceiling in front of the original, to offer extra isolation. For this upgrade to work you need to make sure that the independent wall or ceiling is not directly connected to the existing failed partition; so it provides isolation between materials.

Coupled_wall_construction

Noise flanking can also be down to the use of down to the use of lightweight blocks in the construction of the building envelope. Due to the lightweight mas of the inner wall it allows sound to transmit from dwelling to another, both vertically and horizontally. If a building has failed its sound testing, it is essential to establish if the problem is due to direct transmission, flanking transmission or a combination of both so that the most cost and time effective remedial treatment can be designed and applied to the failed partitions.

If you require more information about acoustic design and/or sound testing on your project, please contact us now at info@aptsoundtesting.co.uk or call me direct on 07775623464.