Remedial action following a sound insulation test failure

Remedial action following a sound insulation test failure

If a partition fails a sound insulation test, it can be difficult to provide definitive guidance on resolving specific problems that have occurred in individual buildings as the building is usually complete at the time of testing. However, using our knowledge of acoustic construction and detailing APT Sound Testing are usually able to identify and resolve any problems with the acoustic partitions.

ACOUSTIC_DESIGN

If the sound testing failure is attributed to the construction of the separating and/or associated flanking elements, other rooms that have not been tested as part of the testing schedule may also fail to meet the test performance levels. Additional tests may be needed, over and above the number recommended under Building Regulations Part E.

Extra sound testing will assist in identifying, at an early stage, where the failures have been caused by intermittent poor workmanship and/or design. Sound Testing may then be required for all plots to identify the ones that require remedial treatment. Where failure is due to a design fault, additional testing may not be required, as all plots with the same design are likely to require remedial treatment and so a generic acoustic upgrade can be undertaken to the failed partitions and then retested thereafter.

sound testing

To try and negate potential problems with the sound insulation testing we offer the following 4 step acoustic design advice package:

  1. Site Survey Visits – to let us view the existing site construction. This allows us to check for potential problematic construction detailing and also lets us check that the installation teams are installing the acoustic materials as per manufacturer’s guidelines.
  2. Sample Sound Testing – of the existing construction. This offers an accurate overview of the acoustic performance of the existing partitions.
  3. Design Review – a full design review of the proposed developments party walls and floors.
  4. Pre-completion Sound Testing to satisfy Approved Document E.

APT Sound Testing can supply a ‘one stop’ solution for all your acoustic requirements. If you would like more information in regards to sound insulation testing or acoustic design please contact us at: info@aptsoundtesting.co.uk  or call Darren direct on 07775623464.

Preparing for your site for Sound Testing

Preparing for your site for Sound Testing

To record accurate test measurements, we need to ensure that the correct site conditions are achieved prior to the precompletion sound testing. Relatively quiet conditions are required on site throughout the testing. Any site operatives working in the testing area will have to leave temporarily and any noisy works in the vicinity of the test areas including external site activity such as groundworks, drilling and banging will need to be halted, otherwise it may result in a sound test failure.  We always provide a full sound testing checklist within our quotation which identifies what actions need to be undertaken prior to the sound test.

sound testing equipment

The condition the buildings/dwelling is very important, as they can influence the results of the test. The following stages for sound testing will help preparation and also assess the point at which completed buildings can be tested. Generally before the test the parts of the building/rooms either side of the separating wall or separating floor should be complete. Particular attention should be paid to the following:

  1. All separating floors and walls and all flanking walls and floors should be complete.
  2. All wall and floor junctions should be complete – to include flanking strips etc.
  3. All wall finishes should be complete, this should include skirting’s being in place. This does not include decorative finishes such as paint.
  4. Floors must be bare and no carpets should be laid – where a concrete floor with bonded resilient cover is to be fitted with wood based flooring. In this case, the test sample resilient floor cover should be tested with a wood based floor covering laid over the test sample area.
  5. Windows should be installed with all glass fitted.
  6. Trickle vents should be in place and closed.
  7. All doors should be fully fitted and closed. This includes internal doors and external doors fully fitted with doors seals.
  8. Services should be complete and any voids around ducts finished.
  9. Electrical sockets should be fitted.
  10. A 240V electricity supply should be available to all the test plots.
  11. There should be no noise during the test other than from the testing equipment.
  12. The test plots and adjacent areas within the building should be quiet for the duration of the test.
  13. No work should be carried out or noise made in the building at the time of the test.
  14. Site workers should not enter the building or be in the parts of the building undergoing a test.

We try to offer a ‘one stop acoustic solution’ visa our acoustic design service, sample sound testing and site visits.

If you would like APT Sound Testing to review your sites acoustic construction, then please speak to us about our acoustic design service, alternatively if you just require sound insulation testing please contact us at: info@aptsoundtesting.co.uk

Sound Insulation Testing

Sound Insulation Testing

At APT we offer Airborne and Impact Sound Insulation Testing in accordance with Part E of the Building Regulations and, where required sound testing on Schools BB93 & BREEAM. Under Part E of Building Regulations, this is a requirement for new and converted dwellings where there is a separating partition wall or floor. The sound insulation testing of existing buildings is carried out to assess current levels of sound insulation and to allow for the design of remedial measures, where the performance needs to be increased.

The buildings that currently require sound testing are:

  1. Dwelling-houses, flats or rooms for residential purposes created by conversion of existing buildings or new build rooms for residential purposes will need to be tested if work starts after 1 July 2004.
  2. New build dwelling-houses and flats will need to be tested if work starts after 1 July 2004.

Sound insulation testing is carried out to ensure that minimum standards of sound resistance have been met to ensure the well-being of new tenants is not compromised by adverse sound transmission. The testing checks that the dividing partitions have not been compromised by poor workmanship and poor design. We use the latest sound testing equipment as shown below:

sound testing equipment

You are normally required to undertake sound testing to each type of construction, i.e. if you have a mixture of brick, block-work, timber and metal stud-work walls all four types would need to be tested, followed by a 10% sample of that type. it is worth noting that if any test failures occur, then the number of sound tests may need to increase on the development.

If you are unsure whether the Regulations apply to your development or if your site needs sound insulation testing, please call your local office or email us at info@aptsoundtesting.co.uk where our team will be happy to discuss all aspects of acoustics or sound insulation within buildings, and explain the testing procedure.

Good Acoustic Design

Good Acoustic Design to Pass Your Sound Insulation Testing

We have carried our hundreds of acoustic design reviews and sound insulation tests, so we are well placed to help you overcome any potential problems to achieve compliance with Building Regulations Part E.

It is essential that good acoustic design is actioned from the offset of any new construction project. When designing acoustic partitions you will need to consider the following

architect drafting a house blueprint

  1. The careful design of floor plans to avoid habitual rooms being placed side by side.
  2. The mass and density of products that you are using.
  3. Using good design detailing to ensure the careful isolation of materials.
  4. The whole construction detail and how it is made up.
  5. Undertaking careful acoustic detailing of junctions between walls, ceilings and floors.
  6. Using acoustic wall ties in cavity walls.
  7. Types of doors in sound resisting walls.
  8. Containment of noise within noisy parts of a building such as lift shafts.
  9. Positions of sockets and flues on opposite sides of walls to ensure they don’t sit back to back.
  10. Sealing and filling of joints.
  11. The use of cavity closer’s on window/door reveals.
  12. Careful sealing of service penetrations.
  13. Designing to reduce potential reverberation in common parts of buildings such as corridors and entrance areas and the subsequent use of absorbent materials.

Unfortunately unless the acoustic design has been taken into account, the floor and ceiling partitions can be the main pathways for sound transmission.  The first type of sound transmission is airborne sound such as TV and speech; and the second is the passage of impact sounds such as footfall or children’s toys being dropped on the floor above.  Achieving good airborne and impact sound isolation requires careful acoustic design considerations.

APT Sound Testing can advise on all types of acoustic design, whether it’s accomplished during initial construction or during a refurbishment/renovation project. We also undertake UKAS accredited sound testing providing a ‘one stop’ solution for all your acoustic requirements.

If you would like more information in regards to good acoustic design and/or sound testing please follow our blog at: http://soundtestinguk.blogspot.co.uk or contact us at: info@aptsoundtesting.co.uk and 07775623464 or visit our website at: www.aptsoundtesting.co.uk

 

Sound Insulation Testing in London

Sound Insulation Testing in London

Unless plans were fully approved prior to 1 July 2003, sound insulation testing will be required on your London development between rooms or spaces that share a common area of separating wall and/or floor as stipulated in Building Regulations Part E for the passage of sound. Sound insulation Testing is not generally required for internal walls and floors within a dwelling-house, flat or room for residential purposes; however all internal partitions should be designed to achieve 40dB.

The buildings that require sound testing are:

  1. Dwelling-houses, flats or rooms for residential purposes created by conversion of existing buildings or new build rooms for residential purposes will need to be tested if work starts after 1 July 2004.
  2. New build dwelling-houses and flats will need to be tested if work starts after 1 July 2004.

The main aim of Sound testing in London is to ensure that minimum standards of sound resistance have not been compromised by poor workmanship and/or poor design. You are normally required to undertake sound testing to each type of construction, i.e. if you have a mixture of brick, blockwork, timber and metal studwork walls all four types would need to be tested, followed by a 10% sample of that type using the equipment shown in Plate A below.

Plate A – Our Sound Test Equipment.

sound testing equipment

For instance, if you have a project with 25 flats you would be required to do 3 x 6 pack of tests; each 6 pack contains 2 airborne wall, 2 airborne floor and 2 impact sound tests; however if any test failures occur, then the number of sound tests may need to increase on the development. When sound test failures occur, then the design and construction of the failed partitions will need to be revisited to try and evaluate the reasons for the failure; thereafter, agreement can be reached on how to rectify problem.

APT Sound Testing can advise on all types of acoustic design, whether it’s accomplished during initial construction or during a refurbishment/renovation project. We also undertake UKAS accredited sound testing providing a ‘one stop’ solution for all your acoustic requirements.

If you would like more information in regards to sound insulation testing please follow our blog at: http://soundtestinguk.blogspot.co.uk or contact us at: info@aptsoundtesting.co.uk and 07775623464 or visit our website at: www.aptsoundtesting.co.uk

Noise Damping to Improve Sound Testing

Noise Damping to Improve Sound Testing 

Noise damping is the most efficient and effective ways to control vibration and noise radiation at the source. Damping materials lessen this noise by turning the vibration into a low-grade heat. By using viscoelastic materials, it changes the resonant frequency of a substrate. By combining vibration damping materials and sound absorbers a composite acoustic construction can be achieved, that can control both airborne and structure borne noise – the final element for good soundproofing.

acoustic_wall_upgrade

It is worth noting that a  large number of manufacturers now produce a wide range of systems designed to improve sound insulation in homes and commercial buildings. In all instances, the effectiveness of these materials will vary depending on the situation in which they are installed. When choosing the acoustic product/s, detailed information on the likely sound insulation performance should be requested from the supplier. If you have an existing property you should check the existing construction of the dividing wall/floor partitions and work back from there. You are advised to give careful consideration to the data supplied by a manufacturer before using a proprietary product. it is also worth noting that the sound insulation value/s given for each product will be ‘best case’ as they have been tested in laboratory conditions and not on site – this is usually worse result by up to 3-5 dB) which may be the difference between a sound test pass or failure.

acoustic_floor_roll_

Also when undertaking remedial work to improve the sound insulation, the acoustic materials are often quite heavy which may result in considerable weight being added to the structure of a property. Thus it is essential to check that the ceiling or floor joists can carry the increased loads satisfactorily.

So in a nutshell if you allow for the following four main elements of sound insulation on your acoustic partition design; Decoupling, Absorption, Mass and Damping, your development should pass the sound insulation test at the first attempt.

If you would like more information in regards to acoustic design and sound insulation testing, please contact us now at info@aptsoundtesting.co.uk or call Darren direct on 07775623464.

Noise Problems in Refurbished Industrial Buildings

Noise Problems in Refurbished Industrial Buildings

We often get asked to undertake a series of sound test measurements to establish the acoustic performance of the wall of floors construction in existing buildings where the dwelling owners are concerned about excess noise.

In recent years the refurbishment of old industrial buildings into residential dwellings has become a very popular. Frequently the existing finishes of existing concrete, brick or wood Noise Problems in Refurbished Industrial Buildingsare left as the interior finish, supposedly to provide the “loft” type of décor. Such designs require even more acoustic design attention if sound privacy is to be achieved. Potential noise problems in refurbished industrial buildings can be quite challenging so buyers should insist that actual on-site sound insulation testing is undertaken to check the building has complied with the sound design performance criteria of Building Regulations Part E.

sound_transmission_through_floors

If you think you have a sound problem in your dwelling and are seeking help to resolve the problem, be sure to contact us and describe the problem in as much detail as possible. Describe the nature of the sounds, when and where you can hear it. Is it impact noise or airborne noise or a combination of both? If the unit is of recent construction you may need to procure a set of architectural drawings and mark-up which partitions noisiest. The more information you can provide us, the quicker we can try to determine the nature of the problem and subsequently find an acoustic solution for the partition/s.

We can also visit site and undertake sample testing on the dividing partitions. If the partitions fail the tests we can identify the main reasons for the sound test failures so targeted remedial treatments can be undertaken.

If you have a project that requires acoustic design advice or sound insulation testing, then please contact us at: info@aptsoundtesting.co.uk or phone me directly on 07775623464.

 

Sound Transmission Though Windows

Sound Transmission Though Windows

One source of great annoyance is often due to sound transmission though windows, this can be down to a variety of factors. If the windows are operable types, the first thing to check is to see if the widows close properly against their seals and any weather stripping is continuous and in good order. If the window leaks air, then more often than not it will usually leak sound. If the window closes to form a tight seal and the weather-stripping seems adequate the next thing to check is the window frame.

Noise_Problems_Failed_Sound_Testing

Windows are frequently installed in to the wall opening with plastic shims to insure the unit is plumb and level. The space between the frame and the wall should be insulated and sealed before the window casings are installed. If this was not done correctly you can probably detect the sound leakage by placing your ear close to the frame and listening.

Usually double pane windows have poor noise-stopping capabilities. This may be overcome by installing a layer of lamination. Many manufacturers offer this service but it can be quite costly. Although double pane windows do stop a bit more noise than single pane windows it is still not very effective. In a noisy environment, you would hardly notice the difference.

Part of the problem is down to the construction of double pane windows; this is because the two pieces of glass are coupled within the same frame and vibrate together, similar to a tuning fork. Sound insulation, however, is increased markedly by using a double pane system and replacing air by argon between the panes.

In some cases the thickness of the glass maybe the problem in which case it may be necessary to install another layer of glass on the inside of the existing frame making sure that the additional pane of glass is well sealed into the opening.

If you have a project that requires acoustic design advice or sound insulation testing, then please contact us at: info@aptsoundtesting.co.uk or phone us directly on 07775623464.

Our Sound Testing Procedure

Our Sound Testing Procedure

Our sound testing procedure is quite simple and our acoustic engineer will be happy to explain this on site. Essentially, for party walls there is one type of sound insulation test which is airborne sound test and for compartment floors there are two types of sound insulation tests which are airborne and impact sound insulation tests. The airborne sound insulation test is carried out by means of a loudspeaker emitting a steady source of noise on one side of the partition (wall or floor) to be measured. The corresponding sound level is measured on the other side of the partition.

sound testing equipment

Impact sound insulation tests are carried out by means of a tapping machine placed on the floor sample to be measured and the noise measured in the room or space below. Calculations are done based on these measurement and the above mentioned parameters are calculated and compared to the Building Regulations Part E sound insulation requirements for the given type of the building. It is important that the building to be sound tested is completely finished and sealed with no sound leakage through doors and windows.  Please see our check list for sound insulation testing for more information.

The airborne and impact sound insulation tests carried out in full accordance with the measurement procedures of BS EN ISO 140-4:1998[3] for field measurements with a single figure DnTw and LnTw in accordance with BS EN ISO 717. As per the new regulations the Spectrum Adaptation Ctr which is a correction factor calculated from the measured DnT.w and the corresponding third octave band DnT values.  It uses a set of weighting levels in third octave bands derived from a road traffic noise spectrum.  It is applied to airborne test results and is measured in dB.

If you would like advice on your acoustic design or sound testing in London, please contact us now at info@aptsoundtesting.co.uk or call us on 07775623464

SOUND TESTING FOR LONDON

SOUND TESTING FOR LONDON

London is a massive city containing in excess of 5 million dwellings, many sharing wall and floor partitions. In this noisy environment it is essential that good acoustic design and construction is incorporated into all new and refurbishment projects along with sound testing for London.

To try and help enforce good acoustic design principles, pre-completion sound testing was introduced in July 2003 to comply with new Approved Document E. The new building regulations required 10% of each party wall/floor construction type to be sound tested on all new build and conversion properties.

We have undertaken thousands of sound tests on converted properties in London and in our experience if the partitions haven’t received any acoustic upgrades the wall and floor partitions – as per the plate below) normally achieve approx. 30-35dB for airborne sound and 68-74dB for Impact Sound. Obviously these figures fall well short of the required 43dB & 64dB as stipulated in Approved Document E. Also, it’s worth taking into account that sound doubles every 10dB, so 30-35dB for airborne sound and 68-74dB for impact sound would be massive failures and careful acoustic design and construction upgrades would be required.

Detail 1: Existing Floor Partitions (rated at approx. 30-35dB)

Failed_sound_Testing_Due_to_existing_floor_Construction_

Using our many years’ experience in building acoustics, we are able to offer a total design and testing solutions for new and conversion projects. We help many architects and top 10 construction companies with their acoustic design requirements from the largest developments containing hundreds of units through a pair of semi-detached dwellings. We always endeavour to find the best solution, always taking build-ability and cost into consideration.

If it’s a conversion project and you are unsure of the floor/wall construction, we often recommend our ‘sample sound testing service. Firstly, we visit site and undertake sample sound testing to at least one floor and wall partition, is consists of at least one airborne and impact test to the proposed dividing floor and an airborne test to the dividing wall. Once the sound test results are established we can then offer a targeted acoustic design solution to achieve a successful sound test in London in compliance with Approve Document E.

Whatever the problem we can usually find an acoustic solution that will help you achieve Building Regulation compliance  If you have a project that’s needs acoustic design advice or needs sound insulation testing then please contact us at: info@aptsoundtesting.co.uk