GOOD ACOUSTIC DESIGN AND CONSTRUCTION

GOOD ACOUSTIC DESIGN AND CONSTRUCTION

Unfortunately there are many misconceptions when it comes to acoustic design and construction. Unfortunately by simply constructing a good separating wall or floor this may not in itself provide sufficient sound insulation to pass the sound testing for Part E as the junctions of each separating wall and/or floor with other parts of the building are equally as important. There may be other potential issues such as flanking sound transmission that can occur via construction components such as:

  1. the internal partitions
  2. the inner leaf of the external wall
  3. the external wall cavities
  4. the external façade or outer leaf
  5. the roof structure
  6. the foundations.

The overall design and construction system should therefore be considered and not just the separating wall or floor partitions.  Flanking sound transmission may in some cases be the dominant pathway between adjoining dwellings, especially in existing buildings where you are planning to convert offices/large houses into flats where there are large existing penetrations through the floors.

NoiseFlankingWall

Also, it is never safe to assume because the architect has specified high performance walls, windows and floor/ceiling assemblies that the materials and onsite workmanship will result in compliance with the anticipated results. You should usually reduce the acoustic target by 4-5dB due to onsite construction. When the construction assembly is tested in the lab, it is also certified and the installation techniques are described and undertaken in great detail.  Unfortunately it is not always possible to replicate the exact conditions on the site compared to the ideal conditions within in a lab setting, which is a far more controlled and scrutinised environment. This is the reason why a 5 point difference is allowed between the construction design on paper and the actual on site sound insulation performance.

APT Sound Testing can advise on all types of acoustic design, whether it’s accomplished during initial construction or during a refurbishment/renovation project.  We have the technical experience to help identify and rectify your soundproofing or noise control problem.

If you would like more information in regards to sound testing please follow our blog at: http://soundtestinguk.blogspot.co.uk or contact us at: info@aptsoundtesting.co.uk or visit our website at: www.aptsoundtesting.co.uk

Broken Down Rating Methods for Sound Testing

Broken Down Rating Methods for Sound Testing 

The sound insulation rating methods that follow are defined in:

Sound insulation testing is usually undertaken near the end of a project to show that the party wall and floor partitions meet the standards shown in Building Regulations Approved Document E.  The method for testing for airborne and impact sound insulation is in full accordance with: the suggested methods presented in BS EN ISO 140-parts 4 & 7: 1998. Sound tests are broken down into various rating methods.

sound testing equipment

The sound insulation rating methods that follow are defined in:

 Rating Method – RW

This single figure rating method is the rating used for laboratory airborne sound insulation tests. The figure indicates the amount of sound energy being stopped by a separating building element when tested in isolation in the absence of any flanking paths.

 Rating Method – DnTw

The single figure rating method that gives the airborne sound insulation performance between two adjacent rooms within a building as measured within site conditions. The result achieved is affected not only by the separating element also by the surrounding structure and junction details.

 Rating Method – Ctr

The Ctr adaptation term is a correction that can be added to either the RW (laboratory) or DnTw (site) airborne rating. The Ctr term is used because it targets the low frequency performance of a building element and in particular the performance achieved in the 100 – 315 Hz frequency range. This term was originally developed to describe how a building element would perform if subject to excessive low frequency sound sources, such as traffic and railway noise. This rating is expressed as RW + Ctr and allows the acoustic designer to critically compare performances. The rating method has not been universally welcomed. Some

acousticians believe that the method is too crude as it only considers the low frequency performance, and because site measurements at low frequencies are prone to difficulties, which can lead to a lack of confidence in the results achieved.

 Rating Method – Lnw

This single figure rating method is the rating used forclaboratory impact sound insulation tests on separating floors. The figure indicates the amount of sound energy being transmitted through the floor tested in isolation, in the absence of any flanking paths. With impact sound insulation, the lower the figure the better the performance.

Rating Method – LnTw

The single figure rating method that is used for impact sound insulation tests for floors. The figure indicates the sound insulation performance between two adjacent rooms within a building as measured on site. The result achieved is affected not only by the separating floor but also by the surrounding structure, e.g. flanking walls and associated junction details.

Rating Method – Dncw

The single figure laboratory rating method, which is used for evaluating the airborne sound insulation performance of suspended ceilings. Laboratory tests simulate the room-to-room performance of the suspended ceiling when a partition is built up to the underside of the ceiling with sound transmitted via the plenum.

APT Sound Testing can advise on all types of acoustic design, whether it’s accomplished during initial construction or during a refurbishment/renovation project.  We have the technical experience to help identify and rectify your soundproofing or noise control problem.

If you would like more information in regards to sound testing please follow our blog at: http://soundtestinguk.blogspot.co.uk or contact us at: info@aptsoundtesting.co.uk or visit our website at: www.aptsoundtesting.co.uk

The different types of Sound Testing

The different types of Sound Testing.

There are two distinct types of noise to consider through floors, they are:

  • Airborne Noise (for example speech and music) and
  • Impact Noise (for example footsteps directly on the floor above)

To take this into account there are two different types of Sound Testing required in compliance with Approved Document Part E. Even if both types of sound are emitting through the ceiling/floor then there are some easy installations that should reduce the sound levels and improve your sound test results.

sound testing equipment

To help our clients overcome this problem, we also offer our acoustic design service which helps clients to pass the sound testing upon completion of the acoustic upgrade. By advising on a simple cost effective wall and/or floor upgrade, we are able to forward simple to follow acoustic design reviews, utilising our extensive knowledge of different materials and construction methods. Using this philosophy, to date, we have had no sound test failures where our acoustic upgrades have been incorporated into the site construction, ensuring compliance with Part E of Building Regulations.

Pre-completion sound testing has been a mandatory requirement since July 2003 and all new build properties and conversions which were built after this date require 10% of each party wall/floor construction type to be tested. The Sound testing is to be carried out between pairs of rooms separated by party walls and/or floors. Part E stipulates that it sound testing should take place between dividing partitions between living rooms and bedrooms as these are classed as the two main habitable rooms; however, other rooms can be used if this is not possible such as dining rooms, kitchen and studies.

APT Sound Testing can undertake UKAS accredited Part E sound testing throughout England and Wales. Our sound test engineers carry all the latest class 1 acoustic equipment and we provide full UKAS accredited air and sound testing, so our clients can be sure that all testing is completed to the strictest  ISO quality controlled standards.

If you would like advice on your acoustic design or sound testing in London, please contact us now at info@aptsoundtesting.co.uk or call us on 07775623464

Simple Design Solutions to Pass Part E Sound Testing

Simple Design Solutions to Pass Part E Sound Testing

There are many simple solutions to reduce the noise levels and achieve compliance with Part E sound testing. We can provide easy to follow acoustic design reviews, utilising our extensive knowledge of different materials and construction methods.

Our clients often convert large houses into multiple flats, i.e. a flat on each of the ground, 1st and 2nd floors. They usually leave the floor boards in place and install a layer of plasterboard to the underside of the existing plasterboard/lathe and plaster. Unfortunately this simple type of upgrade usually achieves 30dB for airborne sound, which will result in sound testing failure. The sound test result needs to be 43db and above for airborne noise and 70dB for Impact sound.

Failed_sound_Testing_Due_to_existing_floor_Construction_

One simple solution to overcome the above problem would be to add another ceiling element to the overall construction. This can be achieved by incorporating resilient metal bars which are connected to the underside of the joists and mounted perpendicular (90˚) to the joist direction. If plasterboard has already been tacked to the underside of the joists you can firstly add timber batten and then add the resilient bars, also mounted perpendicular (90˚ to the batten, thereafter 2 x 12.5mm layers of soundboard can be tacked to the underside of the resilient bar and an acoustic insulation added to the newly formed void. In between the joist void add 100mm acoustic insulation. Above the floor boards add an acoustic resilient membrane to lower the chance of impact noise transmitting down to dwelling below.

Acoustic_Ceiling_Upgrade

The aforementioned acoustic design solution will usually result in successful sound testing and compliance with Approved Document Part E.

If you require more information in regards to sound testing and/or acoustic design on your project please visit our site at www.aptsoundtesting.co.uk or contact us at info@aptsoundtesting.co.uk, or call me direct on 07775623464.

Poor Acoustic Design

Poor Acoustic Design 

Sound test failure is often down to poor acoustic design detailing during the design and construction phase of a project.

Sound test failure are often associated with poor acoustic design which allows noise flanking transmission through dividing floor and wall partitions. Unwanted noise travelling along flanking paths can make the building structure vibrate which causes the sound to radiate into your room. One simple cost effective solution is to build another wall or ceiling in front of the original, to offer extra isolation. For this upgrade to work you need to make sure that the independent wall or ceiling is not directly connected to the existing failed partition; so it provides isolation between materials.

ACOUSTIC_DESIGN

One of the main reasons for excessive noise flanking down to the use of lightweight blocks in the construction of the wall construction. Due to the lightweight mas of the inner wall it allows sound to transmit from dwelling to another, both vertically and horizontally. If a building has failed its sound testing, it is essential to establish if the problem is due to direct transmission, flanking transmission or a combination of both so that the most cost and time effective remedial treatment can be designed and applied to the failed partitions.

One way to reduce the chance of sound testing failures due to excessive noise flanking transmission is through a careful consideration to the acoustic design at the start of the project.  Unfortunately, by simply specifying high performance wall and floor partitions, it is no guarantee to adequate sound isolation and successful sound testing.

APT offer preconstruction design advice to help you achieve successful sound testing in London in-line with Building Regulations Part E. We also offer onsite inspection services to ensure that the sound insulation elements are being installed as per manufactures guild-lines, as its not use having a robust design if it not being installed properly on site.

If you require more information in regards to sound testing and/or acoustic design on your project please visit our site at www.aptsoundtesting.co.uk or contact us at info@aptsoundtesting.co.uk, or call me direct on 07775623464.

Noise Flanking Through Steel Columns

Noise Flanking Through Steel Columns.

Unless Steel Columns or beams are isolated from the surrounding wall/floor partition it can lead to noise flanking, particular hollow steel columns. Steel can also provide a strong path for structural impact transmission due to its dense nature.

Pre-conversion sample sound tests should be able to identify whether any columns act as a significant transmission path and whether any acoustic treatment is required to remedy the situation. It may not be necessary to treat the column in all dwellings if flanking is limited, however in many instances the columns will need to be acoustically boxed to prevent sound test failure.

ACOUSTIC_DESIGN

One such acoustic treatment for steel columns or beams would be to construct a free standing metal or timber stud partition around the column, incorporating 50mm insulation quilt and sheeted with two layers of gypsum-based board. Where columns pass through separating floors, as in old bonded warehouses, the junction between column and floor should be well sealed not only for sound insulation but also for fire. The column linings should be double lined with gypsum-based board (minimum mass per unit area 10kg/m2).

Timber beams do not significantly affect the sound insulation performance of a separating floor. However, if a beam has been installed for strengthening, the boxing around the beam may be a single sheet of lightweight board and the board may be fixed directly to the beam resulting in a noise flanking path for airborne and impact sound. This can be resolved by stripping off the boxing, packing any voids with dense mineral wool batt and re-sheeting with two layers of dense gypsum-based sound board.

We hope the above information helps you to understand the potential problems with acoustic design and pre-completion sound testing on your development. If you have a project that’s requires acoustic design advice or sound testing in London, then please contact us at: info@aptsoundtesting.co.uk  or phone us directly on 07775623464.

The two types of sound insulation testing through floors.

There are two distinct types of sound insulation testing through floors, they are:

  1. Airborne Noise (for example speech and music)
  2. Impact Noise (for example footsteps directly on the floor above)

In the event of  both types of sound – Airborne & Impact) are emitting excessive noise through the ceiling/floor, then there are some easy installations that should reduce the sound levels and improve your sound test results.

sound testing equipment

We also offer an acoustic design service which helps clients to pass the sound testing upon completion of the acoustic upgrade. By advising on a simple cost effective wall and/or floor upgrade, we are able to forward simple to follow acoustic design reviews, utilising our extensive knowledge of different materials and construction methods. Where our acoustic upgrades have been incorporated into the site construction, all the pre-completion sound tests have passed, ensuring compliance with Part E of Building Regulations.

Pre-completion sound testing has been a mandatory requirement since 2003 and all new build properties and conversions which were built after this date require 10% of each party wall/floor construction type to be tested. In is usual to test between living rooms and bedrooms as these are classed as the two main habitable rooms; however, other rooms can be used if this is not possible such as study’s, kitchens and dining rooms.

We also carry out a large amount of sound tests in council/housing association blocks, where the residents are experiencing excess noise between the dividing wall and floor partitions.

We provide full UKAS accredited air and sound testing in London, using the latest Class 1 equipment, so our clients can be sure that all testing is completed to a strict ISO quality controlled standard

If you would like advice on your acoustic design or sound testing in London, please contact us now at info@aptsoundtesting.co.uk or call us on 07775623464.

Failed Sound Testing in London?

Failed Sound Testing in London?

When a building fails the Part E Sound Test in London it may be down to a problem with the acoustic construction, this may be down to issues such as noise flanking etc.

Ongoing problems with airborne and structure borne sound are often associated with direct noise flanking transmission through floors and supporting walls and other associated structures such as the external envelope. One common cause of noise flanking and failed sound testing is often associated with the inclusion of lightweight blocks within the construction of the building envelope and/or blocked cavities. It all cases it is essential to establish if your problem is due to direct transmission, flanking transmission or a combination of both so that the most cost effective remedial treatment can be chosen.

Sound Testing in London

Unwanted noise travelling along flanking paths will make the building structure vibrate which causes the sound to radiate into your room. One simple cost effective solution is to build another wall or ceiling in front of the original, but not connected to it (often called an independent wall or ceiling) so it provides isolation between materials.

One way to reduce the chance of flanking transmission is through careful consideration to the design at the start of the project.  Unfortunately, by simply specifying high performance wall and floor partitions it is no guarantee to adequate sound isolation and successful sound insulation testing. APT Sound Testing offer both preconstruction and post construction design solutions to achieve a successful sound testing in-line with Part E of Building Regulations. We also offer onsite inspection services to ensure that the sound insulation elements are being installed as per manufactures guild-lines. Even if both types of sound are emitting through the ceiling/floor then there are some easy installations that should reduce the sound levels and improve your sound test results. By advising on a simple cost effective wall and/or floor upgrade, we are able to forward simple to follow acoustic design reviews, utilising our extensive knowledge of different materials and construction methods

If you have failed a sound test and need acoustic advice on how to overcome the problem then please contact us at info@aptsoundtesting.co.uk or call me direct on 07775623464.

BS8233 Noise Surveys in London

BS8233 Noise Surveys in London

APT Sound Testing have undertaken undertake many BS8233 Noise Surveys in London to comply with local planning conditions.  We are a professional noise and acoustic consultancy firm operating throughout Greater London and the Home Counties.

Our fully qualified and highly experienced engineers provide expert advice and conduct survey analysis into all aspects of sound, such as complying with local planning conditions NEC’s and investigating complaints into excessive noise such as excess plant noise etc.

We have undertaken many BS8233 noise surveys in London  on numerous potential housing and other noise-sensitive sites throughout the Capital and the UK. Our acoustic surveys cater for sites that may be exposed to noise from road, rail or or from noisy industrial activities.

sound testing

We undertake wide range of services from planning noise assessments through to noise mitigation proposals. Where it is proposed to install new plant or equipment, we undertake noise surveys to determine noise emission limits, in line with Local Authority requirements, and provide advice on mitigation. As a London based company we have an in depth knowledge on complying with London planning permissions and local legislation. Our engineers are expertly suited to carry out noise assessments, with a wealth of experience in assessing the sound impact of residential, industrial and commercial businesses in the community.

Noise assessments and reports should be submitted during the pre-application process and discussions on planning applications. In many circumstances a planning condition will stipulate that a noise survey will need to be undertaken.

Planning noise surveys are normally carried out at the design stage of the project prior to the commencement of construction, this is to allow the acoustic design of the building to take into account the local noise levels. If the local noise levels are excessive then a more robust acoustic twill need to be adopted to mitigate any potential noise problems. Thereafter the local authority may also require post a BS 8182 London noise survey to prove that the noise standards have been achieved within the living rooms and bedrooms.

if you would like more information in regards to our BS8233 Planning Noise Surveys, please don’t hesitate to contact us now at: info@aptsoundtesting.co.uk, or call me direct on 07775623464.

SOUND INSULATION TESTING in LONDON

Sound Insulation Testing in London

APT Sound Testing have a massive amount of experience when it comes to undertaking  sound insulation testing in London. We have the necessary know how and onsite experience to carry out sound insulation testing on a new build or conversion project throughout London for a most competitive prices.

Our engineers carry out the airborne and impact sound test measurements in compliance with Part E of Building Regulations. We have previously undertaken hundreds of sound tests to new build and conversion projects. we also undertake detailed design reviews to ensure our clients achieve a successful sound test.

NoiseFlankingWall

Our engineers also understand the extra coordination that’s required to test within central London, whether its restricted access and/or parking we have it covered. Many other companies that are based outside London literally double their fees when undertaking sound testing in the capital; as we have an office in London we can afford to charge the same flat fee as we do across the rest of the UK.  Also as we are based in London we can usually arrive on site at the agreed time which often minimises delays to planned noisy works on site. We aim to arrive early and leave early.

We undertake London sound testing on all types of projects from simple flat conversions to large new apartment block developments containing many hundreds of flats. We also undertake sound testing where a lease holder dispute has arisen, which is quite common in London. We can undertake sample sound testing to highlight the existing sound insulation performance of the dividing wall and/or floor partitions to allow for targeted acoustic design to keep cost and delays to a minimum.

If you would like more information on our London Sound Insulation Testing package please contact us now at info@aptsoundtesting.co.uk or call me directly on 07775623464.